Abstract

To manage the increasing turbine temperatures of future gas turbines a cooled cooling air system has been proposed. In such a system some of the compressor efflux is diverted for additional cooling in a heat exchanger (HX) located in the bypass duct. The cooled air must then be returned, across the main gas path, to the engine core for use in component cooling. One option is do this within the combustor module and two methods are examined in the current paper; via simple transfer pipes within the dump region or via radial struts in the prediffuser. This paper presents an experimental investigation to examine the aerodynamic impact these have on the combustion system external aerodynamics. This included the use of a fully annular, isothermal test facility incorporating a bespoke 1.5 stage axial compressor, engine representative outlet guide vanes (OGVs), prediffuser, and combustor geometry. Area traverses of a miniature five-hole probe were conducted at various locations within the combustion system providing information on both flow uniformity and total pressure loss. The results show that, compared to a datum configuration, the addition of transfer pipes had minimal aerodynamic impact in terms of flow structure, distribution, and total pressure loss. However, the inclusion of prediffuser struts had a notable impact increasing the prediffuser loss by a third and consequently the overall system loss by an unacceptable 40%. Inclusion of a hybrid prediffuser with the cooled cooling air (CCA) bleed located on the prediffuser outer wall enabled an increase of the prediffuser area ratio with the result that the system loss could be returned to that of the datum level.

Publisher

ASME International

Subject

Mechanical Engineering,Energy Engineering and Power Technology,Aerospace Engineering,Fuel Technology,Nuclear Energy and Engineering

Reference23 articles.

1. New Environmental Friendly Aero Engine Core Concepts,2007

2. Aerodynamic Performance of a Coolant Flow Off-Take Downstream of an OGV;ASME J. Turbomach.,2013

3. Performance of Annular Combustor-Dump Diffusers;J. Aircr.,1977

4. Detailed Measurements on a Modern Combustor Dump Diffuser System;ASME J. Eng. Gas Turbines Power,1995