Single-Step Stereolithography of Complex Anatomical Models for Optical Flow Measurements
Author:
de Ze´licourt, Diane1, Pekkan, Kerem1, Kitajima, Hiroumi1, Frakes, and David1, Yoganathan Ajit P.1
Affiliation:
1. Cardiovascular Fluid Mechanics Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University School of Medicine, Room 2119 U.A. Whitaker Building, 313 Ferst Dr., Atlanta, GA 30332-0535
Abstract
Transparent stereolithographic rapid prototyping (RP) technology has already demonstrated in literature to be a practical model construction tool for optical flow measurements such as digital particle image velocimetry (DPIV), laser doppler velocimetry (LDV), and flow visualization. Here, we employ recently available transparent RP resins and eliminate time-consuming casting and chemical curing steps from the traditional approach. This note details our methodology with relevant material properties and highlights its advantages. Stereolithographic model printing with our procedure is now a direct single-step process, enabling faster geometric replication of complex computational fluid dynamics (CFD) models for exact experimental validation studies. This methodology is specifically applied to the in vitro flow modeling of patient-specific total cavopulmonary connection (TCPC) morphologies. The effect of RP machining grooves, surface quality, and hydrodynamic performance measurements as compared with the smooth glass models are also quantified.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference12 articles.
1. Hopkins, L. M., Kelly, J. T., Wexler, A. S., and Prasad, A. K., 2000, “Particle Image Velocimetry Measurements in Complex Geometries,” Exp. Fluids, 29, pp. 91–95. 2. Bale-Glickman, J., Selby, K., Saloner, D., and Savas, O., 2003, “Experimental Flow Studies in Exact-replica Phantoms of Atheroscerotic Carotid Bifurcations under Steady Input Conditions,” ASME J. Biomech. Eng., 125, pp. 38–48. 3. Friedman, M. H. , 1993, “Arteriosclerosis Research Using Vascular Flow Models: From 2-D Branches to Compliant Replicas,” ASME J. Biomech. Eng., 115, pp. 595–601. 4. Chong, C. K., Rowe, C. S., Sivanesan, S., Rattray, A., Black, R. A., and Shortland, A. P., 1999, “Computer Aided Design and Fabrication of Models for in vitro Studies of Vascular Fluid Dynamics,” Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 213, pp. 1–4. 5. Springer, A. M., 1998, “Application of rapid prototyping methods to high-speed wind tunnel testing,” Project 96-21, NASA Marshall Space Flight Center Technical Publication 1998-05-01.
Cited by
47 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|