Affiliation:
1. US Air Force Wright Laboratory, Wright-Patterson AFB, OH
Abstract
This study investigated the adiabatic wall cooling effectiveness of a single row of film cooling boles injecting into a turbulent flat plate boundary layer below a turbulent, zero pressure gradient freestream. Levels of freestream turbulence (Tu) up to 17.4% were generated using a method which simulates conditions at a gas turbine combustor exit. Film cooling was injected from a single row of five 35 degree slant-hole injectors (length/diameter = 3.5. pitch/diameter = 3.0) at blowing ratios from 0.55 to 1.85 and at a nearly constant density ratio (coolant density/freestream density) of 0.95. Film cooling effectiveness data is presented for Tu levels ranging from 0.9% to 17% at a constant freestream Reynolds number based on injection hole diameter of 19000. Results show that elevated levels of freestream turbulence reduce film cooling effectiveness by up to 70% in the region directly downstream of the injection hole due to enhanced mixing. At the same time, high freestream turbulence also produces a 50–100% increase in film cooling effectiveness in the region between injection boles. This is due to accelerated spanwise diffusion of the cooling fluid, which also produces an earlier merger of the coolant jets from adjacent holes.
Publisher
American Society of Mechanical Engineers
Cited by
12 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献