Supercritical CO2 Brayton Cycle Power Generation Development Program and Initial Test Results

Author:

Wright Steven A.1,Pickard Paul S.1,Fuller Robert2,Radel Ross F.1,Vernon Milton E.1

Affiliation:

1. Sandia National Laboratories, Albuquerque, NM

2. Barber Nichols Inc., Arvada, CO

Abstract

The DOE Office of Nuclear Energy and Sandia National Labs are investigating supercritical CO2 Brayton cycles as a potentially more efficient and compact power conversion system for advanced nuclear reactors, and other heat sources including solar, geothermal, and fossil or bio fuel systems. The focus of this work is on the supercritical CO2 Brayton cycle which has the potential for both high efficiency, in temperature range (400–750 C), and for reduced capital costs due to very compact turbomachinery. The cycle achieves high efficiency due to the non-ideal behavior of supercritical CO2, and it achieves extremely high power density because the fluid in the turbomachinery is very dense, 10%–60% the density of water. Sandia and its contractor Barber Nichols Inc. have fabricated and are operating a supercritical CO2 (S-CO2) compression test-loop to investigate the key technology issues associated with this cycle. The compression loop is part of a multi-year phased development program to develop a megawatt (MW) heater-class closed S-CO2 Brayton cycle to demonstrate the applicability of this cycle to heat sources above 400 C. Other portions of the program include modifications to the compression loop to operate it as a simple heated Brayton loop by adding a small turbine and a heater, but with no recuperator. The early testing of this simple Brayton cycle is under way. A more ambitious effort is currently constructing a recompression cycle Brayton loop (1) which is some times called a split-flow Brayton cycle. This cycle is used to increase the efficiency of the system by providing large amounts of recuperation using printed circuit heat exchangers. The re-compression (or split-flow) Brayton cycle is designed to operate at 1000 F (538 C) and produce up to 250 kWe with a 1.47″ OD radial compressor and a 2.68″ OD radial turbine. The current compression loop uses a main compressor that is identical to the main compressors in all the Brayton cycles that are being developed at Sandia. The key issues for the supercritical Brayton cycle include the fundamental issues of compressor fluid performance and system control near the critical point. Near the critical point very non ideal fluid behavior is observed which means that standard tools for analyzing compressor performance cannot be used. Thus one of the goals of the program is to develop data that can be used to validate the tools and models that are used to design the turbomachinery. Other supporting technology issues that are essential to achieving efficiency and cost objectives include bearing type, thrust load and thrust load balancing, bearing cooling, sealing technologies, and rotor windage losses. The current tests are providing the first measurements and information on these important supercritical CO2 power conversion system questions. Some of this data is presented in this report. In the testing to date, the turbomachinery has reached maximum speeds of 65,000 rpm, peak flow rates of over 9 lb/s and pressure ratios of just over 1.65. Compressor inlet fluid densities have been varied from 14% to 70% the density of water. Although the data from these tests are only the first results to be analyzed, they indicate that the basic design and performance predictions are sound. The loops have operated the turbo-compressor on the liquid and vapor side of the saturation curve, very near the critical point, above the critical point and even on the saturation dome. We have also operated the compressor near the choked flow regime and even in surge. At the current operating speeds and pressures, the observed performance map data agrees extremely well with the model predictions. These results have positive implications for the ultimate success of the S-CO2 cycle. In general the main compressor shows no adverse behavior while operating over a wide range of normal operating conditions. It operates reliably and with performance values that are very near the predicted results. Future efforts will focus on operating the Brayton cycle loop at sufficiently high temperatures that electrical power can be produced near the end of 2009. The compression-loop hardware is now the test bed for confirming the remaining parameters to support the next stage of development — which is the 1 MW heater-class split-flow or re-compressor Brayton cycle.

Publisher

ASMEDC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3