A Compact, Bone-Attached Robot for Mastoidectomy

Author:

Dillon Neal P.1,Balachandran Ramya2,Fitzpatrick J. Michael3,Siebold Michael A.3,Labadie Robert F.2,Wanna George B.2,Withrow Thomas J.1,Webster Robert J.1

Affiliation:

1. Department of Mechanical Engineering, Vanderbilt University, 2301 Vanderbilt Place, PMB 351592, Nashville, TN 37235 e-mail:

2. Department of Otolaryngology, Vanderbilt University Medical Center, 1215 21st Avenue South, MCE 10450, Nashville, TN 37232 e-mail:

3. Department of Electrical Engineering and Computer Science, Vanderbilt University, 2301 Vanderbilt Place, PMB 351679, Nashville, TN 37235 e-mail:

Abstract

Otologic surgery often involves a mastoidectomy, which is the removal of a portion of the mastoid region of the temporal bone, to safely access the middle and inner ear. The surgery is challenging because many critical structures are embedded within the bone, making them difficult to see and requiring a high level of accuracy with the surgical dissection instrument, a high-speed drill. We propose to automate the mastoidectomy portion of the surgery using a compact, bone-attached robot. The system described in this paper is a milling robot with four degrees-of-freedom (DOF) that is fixed to the patient during surgery using a rigid positioning frame screwed into the surface of the bone. The target volume to be removed is manually identified by the surgeon pre-operatively in a computed tomography (CT) scan and converted to a milling path for the robot. The surgeon attaches the robot to the patient in the operating room and monitors the procedure. Several design considerations are discussed in the paper as well as the proposed surgical workflow. The mean targeting error of the system in free space was measured to be 0.5 mm or less at vital structures. Four mastoidectomies were then performed in cadaveric temporal bones, and the error at the edges of the target volume was measured by registering a postoperative computed tomography (CT) to the pre-operative CT. The mean error along the border of the milled cavity was 0.38 mm, and all critical anatomical structures were preserved.

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Reference25 articles.

1. Development of a Surgical Robot for Cementless Total Hip Arthroplasty;Clin. Orthop. Relat. Res.,1992

2. Image-Directed Robotic System for Precise Robotic Surgery Including Redundant Consistency Checking,1992

3. Robot Assisted Knee Surgery;IEEE Eng. Med. Biol. Mag.,1995

4. Image-Guided Technique in Neurotology;Otolaryngol. Clin. North Am.,2007

5. Development of the First Force-Controlled Robot for Otoneurosurgery;Laryngoscope,2003

Cited by 26 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Burr Hole Endoscopic Mastoidectomy: A Morphometric Cadaveric Study;Journal of Neurological Surgery Part B: Skull Base;2024-01-04

2. Endoscopic Endonasal Trans-Sphenoidal Minimally Invasive Pituitary Surgery with Image Guided Navigation System (Igns): Learning Experience of Ent Surgeon;Indian Journal of Otolaryngology and Head & Neck Surgery;2023-11-14

3. Vibration Feedback Control for Robotic Bone Milling;IEEE Transactions on Industrial Electronics;2023-10

4. A 2-DOFs Planar Grinding End-Effector for Robotic Laminectomy;2023 WRC Symposium on Advanced Robotics and Automation (WRC SARA);2023-08-19

5. Robots and firm innovation: Evidence from Chinese manufacturing;Journal of Business Research;2023-07