A Nonlinear Axisymmetric Model With Fluid–Wall Interactions for Steady Viscous Flow in Stenotic Elastic Tubes

Author:

Tang D.1,Yang J.2,Yang C.3,Ku D. N.4

Affiliation:

1. Mathematical Sciences Department, Worcester Polytechnic Institute, Worcester, MA 01609

2. Computer Science Department, University of Pittsburgh, Pittsburgh, PA 15260

3. Mathematics Department, Beijing Normal University, Beijing, China

4. Georgia Institute of Technology, School of Mechanical Engineering, Atlanta, GA 30332

Abstract

Arteries with high-grade stenoses may compress under physiologic conditions due to negative transmural pressure caused by high-velocity flow passing through the stenoses. To quantify the compressive conditions near the stenosis, a nonlinear axisymmetric model with fluid–wall interactions is introduced to simulate the viscous flow in a compliant stenotic tube. The nonlinear elastic properties of the tube (tube law) are measured experimentally and used in the model. The model is solved using ADINA (Automatic Dynamic Incremental Nonlinear Analysis), which is a finite element package capable of solving problems with fluid–structure interactions. Our results indicate that severe stenoses cause critical flow conditions such as negative pressure and high and low shear stresses, which may be related to artery compression, plaque cap rupture, platelet activation, and thrombus formation. The pressure field near a stenosis has a complex pattern not seen in one-dimensional models. Negative transmural pressure as low as −24 mmHg for a 78 percent stenosis by diameter is observed at the throat of the stenosis for a downstream pressure of 30 mmHg. Maximum shear stress as high as 1860 dyn/cm2 occurs at the throat of the stenoses, while low shear stress with reversed direction is observed right distal to the stenosis. Compressive stresses are observed inside the tube wall. The maximal principal stress and hoop stress in the 78 percent stenosis are 80 percent higher than that from the 50 percent stenosis used in our simulation. Flow rates under different pressure drop conditions are calculated and compared with experimental measurements and reasonable agreement is found for the prebuckling stage.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference47 articles.

1. ADINA R & D, Inc., 1995a, Theory and Modeling Guide, Watertown, MA.

2. ADINA R & D, Inc., 1995b, ADINA Verification Manual, Watertown, MA.

3. Aoki T. , and KuD. N., 1993, “Collapse of diseases arteries with eccentric cross section,” J. Biomechanics, Vol. 26, 2, pp. 133–142.

4. Bathe, K. J., 1996, Finite Element Procedures, Prentice-Hall, Inc., New Jersey.

5. Bathe, M., 1998, “A fluid–structure interaction finite element analysis of pulsatile blood flow through a compliant stenotic artery,” B. S. Thesis, MIT.

Cited by 44 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3