Characterization of the Discrepancies Between Four-Dimensional Phase-Contrast Magnetic Resonance Imaging and In-Silico Simulations of Cerebrospinal Fluid Dynamics

Author:

Heidari Pahlavian Soroush1,Bunck Alexander C.2,Loth Francis1,Shane Tubbs R.345,Yiallourou Theresia6,Robert Kroeger Jan2,Heindel Walter7,Martin Bryn A.1

Affiliation:

1. Conquer Chiari Research Center, Department of Mechanical Engineering, The University of Akron, Akron, OH 44325 e-mail:

2. Department of Radiology, University Hospital of Cologne, Cologne 50923, Germany e-mail:

3. Children’s of Alabama, Birmingham AL 35233

4. Department of Anatomical Sciences, St. George’s University, St. George, Grenada

5. Centre for Anatomy and Human Identification, Dundee University, Dundee DD1 4HN, UK e-mail:

6. Laboratory of Hemodynamics and Cardiovascular Technology, EPFL, Lausanne 1015, Switzerland e-mail:

7. Department of Clinical Radiology, University Hospital of Muenster, Muenster 48149, Germany e-mail:

Abstract

The purpose of the present study was to compare subject-specific magnetic resonance imaging (MRI)-based computational fluid dynamics (CFD) simulations with time-resolved three-directional (3D) velocity-encoded phase-contrast MRI (4D PCMRI) measurements of the cerebrospinal fluid (CSF) velocity field in the cervical spinal subarachnoid space (SSS). Three-dimensional models of the cervical SSS were constructed based on MRI image segmentation and anatomical measurements for a healthy subject and patient with Chiari I malformation. CFD was used to simulate the CSF motion and compared to the 4D PCMRI measurements. Four-dimensional PCMRI measurements had much greater CSF velocities compared to CFD simulations (1.4 to 5.6× greater). Four-dimensional PCMRI and CFD both showed anterior and anterolateral dominance of CSF velocities, although this flow feature was more pronounced in 4D PCMRI measurements compared to CFD. CSF flow jets were present near the nerve rootlets and denticulate ligaments (NRDL) in the CFD simulation. Flow jets were visible in the 4D PCMRI measurements, although they were not clearly attributable to nerve rootlets. Inclusion of spinal cord NRDL in the cervical SSS does not fully explain the differences between velocities obtained from 4D PCMRI measurements and CFD simulations.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering