Positron emission tomography 2008 in Germany

Author:

Oehme L.,Lindner O.,Hellwig D.,Kotzerke J.,

Abstract

Summary Aim: The working group on positron emission tomography (PET) of the DGN (German Society of Nuclear Medicine) initiated this first survey to collect and analyse information on the practise of PET in Germany in the year 2008. Methods: A questionnaire was sent to PET performing facilities (medical practices, hospitals, university hospitals and others) for retrospective data acquisition. Details regarding the equipment and examination procedures were examined as well as indications and number of studies. In addition, the role of PET within the diagnostic process was evaluated. Results: Responses from 65 sites were analysed. Their technical equipment consisted of 77 PET scanners (40 of them were combined PET/CT devices). About 63 500 PET studies had been performed with 86% in the field of oncology, 8% in neurology and 3% in cardiology. The radiotracers were labelled with 18F in 91% of the studies, whereas 68Ga was used in 4% and 11C in 3%. The analyses revealed lung tumours as the most investigated tumour entity, followed by malignant lymphoma, tumours of the gastro-intestinal tract and prostate cancer (about 14 000, 6000, 5000 and 2000). Corresponding to the new scanners and software procedures, the number of studies with attenuation correction by CT was high (68%) and nearly all studies were reconstructed iteratively (99%). The PET images were analysed quantitatively in the majority of cases (91%). The clinical reports, which included image documentation for the greater part, were posted regularly within 3 days. However, in 70% of the sites electronic transfer possibilities were used additionally to speed up the diagnostic process. The high standard of quality was demonstrated by the fact, that 40 facilities were engaged in a tumour board. Further on, one third of the physicians had gained a PET certification awarded by the DGN. Conclusion: Relative to the high general standard of diagnostic instrumentation in Germany, PET is less established, in particular when compared with other industrialised countries such as USA and Switzerland.

Publisher

Georg Thieme Verlag KG

Subject

Radiology Nuclear Medicine and imaging,General Medicine

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3