Abstract
This paper presents the results of an experimental investigation on blockwork masonry prisms to study the effect on their compressive strength and behaviour of the following factors: (a) concrete infill and mortar strengths; (b) specimen height-to-thickness ratio; (c) specimen length-to-thickness ratio; (d) mortar joint thickness; (e) bond between the block and concrete infill.
Subject
General Materials Science,Building and Construction,Civil and Structural Engineering