Affiliation:
1. Department of Anaesthesiology and Pain Medicine, Ajou University School of Medicine, Suwon, Republic of Korea
2. Department of Thoracic and Cardiovascular Surgery, Ajou University School of Medicine, Suwon, Republic of Korea
Abstract
Haemodynamic changes occurring during heart displacement, using moist laparotomy pads placed behind the heart (PAD group, n = 26) or deep pericardial traction sutures (DPS group, n = 25) to facilitate exposure of the left anterior descending artery during off-pump coronary artery bypass surgery, were compared. Haemodynamic variables were assessed before and 10 min after displacement of the heart. The central venous pressure, mean pulmonary artery pressure and pulmonary capillary wedge pressure increased in both groups. After heart displacement in the PAD group, the cardiac index, stroke volume index, mixed venous oxygen saturation, right ventricular ejection fraction and left ventricular stroke work index decreased significantly, and the systemic vascular resistance and pulmonary vascular resistance increased significantly; these parameters remained unchanged in the DPS group. It was concluded that displacement of the heart using moist laparotomy pads caused significant haemodynamic derangement compared with that caused by deep pericardial traction sutures.
Subject
Biochemistry (medical),Cell Biology,Biochemistry,General Medicine
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献