Hemodynamic comparison between minimally invasive and conventional approaches in off-pump coronary artery bypass grafting: A randomized controlled trial

Author:

Sambandam Kamalakkannan Ganapathy1ORCID,Karthekeyan B Ranjith1ORCID,Shree Shruthi1ORCID,Nagalingam Saranya1ORCID,Rajah Kiran Muthu1ORCID,Gnanachandran Ashok1ORCID

Affiliation:

1. Sri Ramachandra Medical College (SRMC), Chennai, Tamil Nadu, India

Abstract

This study aimed to investigate the hypothesis that minimally invasive coronary artery bypass grafting (CABG) induces fewer hemodynamic alterations compared to conventional approaches, attributing this to reduced heart rotation during grafting. Given the critical role of hemodynamic stability in patient outcomes and the growing popularity of minimally invasive CABG, we sought to assess and compare the hemodynamic responses during left anterior descending artery grafting. This randomized controlled trial was conducted at a tertiary center, enrolling a total of 60 patients, with 30 in each group. Parameters such as heart rate (HR), mean arterial pressure (MAP), central venous pressure (CVP), and perfusion index (PI) were measured at baseline, after octopus stabilization prior to grafting, at 3 minutes during grafting, and at the end of grafting. Additionally, serum lactate levels were assessed at baseline and upon completion of grafting. The baseline HR was comparable between the groups. However, the trends in HR revealed a significant increase in the conventional group after octopus stabilization (P value = 0.0038), at 3 minutes post-initiation of grafting (p < 0.001), and at the completion of grafting (P value = 0.001). MAP and CVP remained comparable at all time points. Notably, PI showed a significant increase in the conventional group during positioning (after octopus stabilization), at 3 minutes post-initiation of grafting, and at the completion of grafting. There were no significant differences in lactate levels between the groups. Despite no significant differences in MAP, CVP, and lactate levels, our findings highlight significant disparities in HR and PI between the two groups. We conclude that the observed variations in heart rate may be attributed to minimal positional changes in the minimally invasive approach compared to the conventional approach.

Publisher

IP Innovative Publication Pvt Ltd

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3