Abstract

Shifted excitation Raman difference spectroscopy (SERDS) can provide effective, chemically specific information on fluorescent samples. However, the restricted ability for fast alternating detection (usually < 10 Hz) of spectra excited at two shifted laser wavelengths can limit its effectiveness when rapidly varying emission backgrounds are present. This paper presents a novel charge-shifting lock-in approach permitting fast SERDS operation (exemplarily demonstrated at 1000 Hz) using a specialized dual-wavelength diode laser (emitting at 829.40 nm and 828.85 nm) and a custom-built charge-coupled device (CCD) enabling charge retention and shifting back and forth on the CCD chip. For six selected mineral samples (moved irregularly during spectral acquisition), results demonstrate superior reproducibility of the fast charge-shifting read-out over the conventional read-out (operated at 5.4 Hz). Partial least squares discriminant analysis revealed improved classification performance of charge-shifting (four latent variables, sensitivity: 99%, specificity: 94%) versus conventional read-out (six latent variables, sensitivity: 90%, specificity: 92%). The charge-shifting concept was also successfully translated to sub-surface analysis using spatially offset Raman spectroscopy (SORS). Charge-shifting SERDS-SORS spectra recorded from a polytetrafluoroethylene layer, concealed behind a 0.25 mm thick, opaque, heterogeneous layer, matched reference spectra much more closely and exhibited a signal-to-background-noise (S/NB) ratio two times higher than that achieved with conventional CCD read-out SERDS-SORS. The novel approach overcomes fundamental limitations of conventional CCDs. In conjunction with the inherent capability of the charge-shifting lock-in technique to suppress rapidly varying ambient light interference demonstrated by us earlier it is expected to be particularly beneficial with heterogeneous fluorescent samples in field applications.

Funder

Science and Technology Facilities Council

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3