A novel assay for triglycerides using glycerol dehydrogenase and a water-soluble formazan dye, WST-8

Author:

Kawano Miki12,Hokazono Eisaku3,Osawa Susumu2,Sato Shouichi2,Tateishi Takiko4,Manabe Masahiro5,Matsui Hirotaka6,Kayamori Yuzo3

Affiliation:

1. Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan

2. School of Health Sciences at Narita, International University of Health and Welfare, Narita, Japan

3. Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka, Japan

4. Department of Medical Laboratory Science, Junshin Gakuen University, Minami-ku, Japan

5. Department of Laboratory Medicine, Kumamoto University Hospital, Kumamoto, Japan

6. Department of Molecular Laboratory Medicine, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan

Abstract

Background The glycerol-3-phosphate (GPO)-peroxidase (POD) chromogenic method is one of the most widely used methods to assay triglycerides. However, it is well known that peroxidase is affected by reducing agents, and recently, it has been reported that some materials affect its activity. Moreover, there is a high possibility of non-specific reaction, as the method uses many enzymes. Against this background, we developed a simpler assay method for triglycerides without using peroxidase. Methods Triglycerides were hydrolysed to glycerol and fatty acids by lipoprotein lipase followed by the oxidation of glycerol to dihydroxyacetone with simultaneous production of NADH by glycerol dehydrogenase. To overcome incomplete conversion of glycerol to dihydroxyacetone by glycerol dehydrogenase at equilibrium, we added 2-(2-methoxy-4-nitrophenyl)-3–(4-nitrophenyl)-5–(2,4-disulfophenyl)-2 H-tetrazolium monosodium salt (WST-8) to the reaction mixture to remove NADH, allowing the reaction to complete while showing stoichiometric production of reduced WST-8. Results The reaction was linear up to 6.4 mmol/L. The mean intra-assay ( n = 20) and inter-assay ( n = 20) imprecision, as determined by replicate analysis of three pooled human serum samples with different triglyceride concentrations, were 1.1–2.3% and 1.1–1.5% coefficient of variation (%CV), respectively. No interference by 2.5 g/L haemoglobin, 65  μmol/L free bilirubin and 359  μmol/L conjugated bilirubin was observed. The equation obtained in comparison with that by the GPO-POD method including endogenous glycerol-eliminating step was: y = 1.0002x + 0.0395 mmol/L; r = 0.999; Sy/x = 0.049 mmol/L; n = 97. Conclusion Our method is an accurate, yet simpler and more sensitive for the quantitative analysis of triglycerides.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine