Affiliation:
1. Eiken Chemical Co. Ltd, Otawara, Tochigi, 329-26, Japan
Abstract
A monoclonal antibody (E-21) was obtained that specifically binds to human pancreatic amylase and shows negligible cross-reaction with human salivary amylase. Using this antibody a radioimmunoassay was developed for pancreatic amylase in human serum. The assay was shown to be sensitive (detectable up to 7 mg/L), reproducible, and specific for pancreatic amylase. In normal subjects, the mean concentration of serum pancreatic amylase determined by this method was 36·3 mg/L with a 95% confidence range of 16·5 to 79·2 mg/L. A good correlation was observed between the concentrations of immunoreactive pancreatic amylase (IR-PA) and enzymatic activities in 20 serum samples ( r = 0·97). The concentration of serum IR-PA was below the detectable limit in pancreatectomised patients, and was greatly increased in patients with acute pancreatitis; the latter was accompanied by parallel changes in total enzymic activity. In patients with mumps, the serum IR-PA level was within the normal range whereas the total enzymic activity was elevated.
Subject
Clinical Biochemistry,General Medicine
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献