Optimization of oestradiol assays to improve utility in an in vitro fertilization setting

Author:

Peavey M1,Akbas N23,Gibbons W1,Zarutskie P1,Devaraj S23

Affiliation:

1. Division of Reproductive Endocrinology and Infertility, Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, TX, USA

2. Department of Pathology and Immunology, Baylor College of Medicine, Houston, TX, USA

3. Texas Children’s Hospital, Houston, TX, USA

Abstract

Background The measurement of oestradiol is an integral component for the management of ovarian stimulation for in vitro fertilization. Automated immunoassays offer fast assay times and high throughput, with less sensitivity and specificity. The aim of this study is to optimize the oestradiol assay in patients undergoing ovarian stimulation for in vitro fertilization via comparison of oestradiol values obtained using two immunoassays compared with mass spectrometry. Methods Patients undergoing ovarian stimulation were prospectively recruited. Serum samples were analysed with ADVIA Centaur® CP Immunoassay, Abbott Architect i1000® immunoassay and AB Sciex 5500 liquid chromatography-tandem mass spectrometry (LC-MS/MS) systems. Per cent bias was determined for each system to report the average tendency of the values to be larger or smaller than the LC-MS/MS value. Linear regression of total follicular volume and oestradiol was computed. Results The ADVIA Centaur® CP assay had a positive bias of 20% compared with LC-MS/MS, while the Architect i1000® had a non-significant, negative bias of 0.3%. With regression fit, a clear, positive relationship was seen between follicular volume and oestradiol. The Architect i1000® assay had a greater correlation (R2 = 0.46) compared with Centaur® CP (R2 = 0.36), when oestradiol values were >1000 pg/mL (3670 pmol/L). Conclusions The Abbott Architect i1000® oestradiol assay exhibits greater agreement with LC-MS/MS and exhibited better correlation to follicular volume when oestradiol values are >1000 pg/mL (3670 pmol/L), prompting a change in the clinic’s oestradiol platform. Attention to assay quality assurance via LC-MS/MS can improve the oestradiol accuracy and permit more informed clinical decisions for improved patient outcomes.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3