Performance of commercially-available cholesterol self-tests

Author:

Kurstjens Steef1,Gemen Eugenie1,Walk Selina1ORCID,Njo Tjin2,Krabbe Johannes34,Gijzen Karlijn5ORCID,Elisen Marc GLM67,Kusters Ron18ORCID

Affiliation:

1. Laboratory of Clinical Chemistry and Hematology, Jeroen Bosch Hospital, Den Bosch, the Netherlands

2. Laboratory of Clinical Chemistry, Saltro, Utrecht, the Netherlands

3. Laboratory of Clinical Chemistry and Laboratory Medicine, Medisch Spectrum Twente, Enschede, the Netherlands

4. Laboratory of Clinical Chemistry, Medlon BV, Enschede, the Netherlands

5. Laboratory of Clinical Chemistry and Hematology, Meander Medical Center, Amersfoort, the Netherlands

6. Laboratory of Clinical Chemistry & Hematology, Elisabeth TweeSteden Hospital, Tilburg, the Netherlands

7. Netherlands Society of Clinical Chemistry & Laboratory Medicine (NVKC), Utrecht, the Netherlands

8. Department of Health Technology and Services Research, Faculty of Behavioural, Management and Social Sciences, Technical Medical Centre, University of Twente, the Netherlands

Abstract

Background Hypercholesterolemia (plasma cholesterol concentration ≥5.2 mmol/L) is a risk factor for cardiovascular disease and stroke. Many different cholesterol self-tests are readily available at general stores, pharmacies and web shops. However, there is limited information on their analytical and diagnostic performance. Methods We included 62 adult patients who required a lipid panel measurement (cholesterol, high-density lipoprotein (HDL), triglycerides and LDLcalc) for routine care. The performance of five different cholesterol self-tests, three quantitative meters ( Roche Accutrend Plus, Mission 3-in-1 and Qucare) and two semi-quantitative strip tests ( Veroval and Mylan MyTest), was assessed according to the manufacturers’ protocol. Results The average plasma cholesterol concentration was 5.2 ± 1.2 mmol/L. The mean absolute relative difference (MARD) of the five cholesterol self-tests ranged from 6 ± 5% ( Accutrend Plus) to 20 ± 12% ( Mylan Mytest). The Accutrend Plus cholesterol meter showed the best diagnostic performance with a 92% sensitivity and 89% specificity. The Qucare and Mission 3-in-1 are able to measure HDL concentrations and can thus provide a cholesterol:HDL ratio. The Passing-Bablok regression analyses for the ratio showed poor performance in both self-tests ( Mission 3-in-1: y = 1.62x–1.20; Qucare: y = 0.61x + 1.75). The Accutrend Plus is unable to measure the plasma high-density lipoprotein concentration. Conclusions/interpretation: The Accutrend Plus cholesterol meter (Roche) had excellent diagnostic and analytic performance. However, several of the commercially-available self-tests had considerably poor accuracy and diagnostic performance and therefore do not meet the required qualifications, potentially leading to erroneous results. Better regulation, standardization and harmonization of cholesterol self-tests is warranted.

Funder

Hartstichting

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3