Effect of collection tube type and freeze–thaw cycles on myeloperoxidase concentrations in blood samples of acute coronary syndrome patients

Author:

Naz Saima1,Ghafoor Farkhanda1,Iqbal Imran Akhtar2

Affiliation:

1. National Health Research Complex, Shaikh Zayed Hospital, Lahore, Pakistan

2. Department of Cardiology, Shaikh Zayed Hospital, Lahore, Pakistan

Abstract

Background Myeloperoxidase has shown potential as a marker for prognosis of coronary artery disease, but presently little is known about preanalytical handling of samples for quantifying myeloperoxidase. The present study was conducted to evaluate the effect of collection tube and freeze–thaw cycles on myeloperoxidase concentrations. Methods Acute coronary syndrome patients ( n = 88) were enrolled after obtaining written informed consent from coronary care unit of a tertiary care hospital (January 2012–June 2014). About 5 mL venous blood was collected from patients and divided into serum, lithium heparin, ethylenediaminetetraacetic acid and sodium citrate tubes. Except serum, all tubes were kept on ice immediately after collection. Samples were centrifuged at −4℃, separated immediately after centrifugation and stored at −40℃ until analysis. Myeloperoxidase was quantified by in-house and commercial assays and re-quantified after five freeze–thaw cycles. Results Myeloperoxidase concentrations, (serum samples) determined by commercial and in-house assays correlated well (r = 0.946) ( P < 0.001) and were higher in serum samples. Within plasma, myeloperoxidase concentrations were slightly higher in ethylenediaminetetraacetic acid (307.7 ± 52.1) and lower in lithium heparin (290.3 ± 49.2) and sodium citrate (221.4 ± 40.3) but not statistically significant. Correlation between myeloperoxidase concentrations (in-house enzyme-linked immunosorbent assay) after first cycle and fifth freeze–thaw cycle dropped to r = 0.448 ( P < 0.001). Conclusion Myeloperoxidase concentrations are comparable in three types of plasma tubes when samples are placed on ice immediately, centrifuged at low temperatures and separated immediately after centrifugation. Multiple freeze–thaw cycles have an effect on myeloperoxidase and should be avoided for quantifying myeloperoxidase.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3