Abstract
In operations, light reflected from biological tissue can be used for disease detection. In this paper, we used a visual entropy evaluation method to design the optimal illuminant to improve colour discriminability of biological tissue. The optimal spectral power distribution of the illuminant was obtained by maximising the visual entropy value of sample tissue based on the human visual system. In the experiment, multispectral imaging was used to measure the spectral reflectance of the tissue and colour clustering was conducted to extract its colour features. To verify the effectiveness of this method, simulated tissue images under illuminations with optimised spectral power distributions were compared with those under other light sources such as the standard illuminant D65 and white LED light sources. Results show that the sample under optimised illumination has a higher visual entropy value with better perceptual visibility.