Forage calibration transfer from laboratory to portable near infrared spectrometers

Author:

Yang Xueping1ORCID,Cherney JH2,Casler MD3,Berzaghi Paolo1

Affiliation:

1. Department of Animal Medicine, Production and Health, University of Padova, Legnaro, Italy

2. Section of Soil and Crop Sciences, School of Integrative Plant Science, Cornell University, Ithaca, NY, USA

3. USDS-ARS, US Dairy Forage Research Center, Madison, WI, USA

Abstract

Portable near infrared (NIR) spectrometers are now readily available on the market and with their smaller size, weight and cost have provided the opportunity to analyze forages both on farms and directly in the field. As new technologies and new portable NIR instruments become available on the market, calibrations for these instruments become a major constraint due to the costs and time necessary to collect reference data. This study evaluated techniques to transfer calibrations for alfalfa and grass forage samples that were developed for a scanning benchtop monochromator (FOSS 6500, 400–2498 nm, LAB) to a diode array instrument (AuroraNir, 950–1650 nm, DA), a digital light processing instrument (NIR-S-G1, 950–1650 nm, DLP) and a short wavelength instrument (SCiO, 740–1070 nm, SCIO). Alfalfa (N = 612) and grass (N = 516) samples from eight agronomic studies were analyzed by wet chemistry for crude protein, neutral detergent fiber (NDF), acid detergent fiber (ADF), in-vitro digestibility (IVTD) and NDF digestibility (NDFD) and divided into calibration, test-set, standardization and inoculation/prediction datasets. Different calibration transfer strategies were evaluated: Spectral Bias Correction (SBC), Shenk and Westerhaus algorithm (SW), Piecewise Direct Standardization (PDS), Dynamic Orthogonal Projection (DOP) or creating a new calibration using LAB predictions of the inoculation/prediction dataset as reference values. All computations for trimming, calibration, validation and standardization were developed using R. SBC with inoculation was an effective method to transfer calibrations for DA. Validation errors for DA transferred calibrations were about 15% lower than LAB for alfalfa data but 6% greater for grass data. For SCIO after DOP spectral adjustment, predicting errors were slightly greater than LAB for both data sets, while prediction errors with DLP were two to three times greater than LAB even after inoculation. PDS created spectral artifacts in the spectra of all three portables, which then resulted in large validation errors. Using LAB predictions as reference values was suitable only for DA, while DLP and DA had large prediction errors. This study showed that calibration sharing between a benchtop and portable instruments is challenging, but possible depending on the portable technologies and the transfer method. Spectral bias correction plus inoculation was the best method to transfer multivariate models for the forage components’ prediction from LAB to handhelds, particularly for DA. Application of DOP was beneficial for SCIO to successfully maintain performance of the original calibration, while for DLP the prediction models were not accurate. Additional studies are necessary to verify these transferring techniques can also be applied to fresh forages, allowing an easier and extended implementation of NIR analysis directly in fields.

Funder

China Scholarship Council

Publisher

SAGE Publications

Subject

Spectroscopy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Research on Near-Infrared Spectroscopy Calibration Transfer Algorithm Based on Piecewise Direct Standardization and K-Nearest Neighbor;2024 5th International Conference on Information Science, Parallel and Distributed Systems (ISPDS);2024-05-31

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3