Application of low-concentration contrast agents and low-tube-voltage computed tomography to chest enhancement examinations: A multicenter prospective study

Author:

Meng Donghua1ORCID,Cui Xiaonan1,Bai Changsen2,Yu Zhongwen3,Xin Lei4,Fu Yufei5,Wang Sicong6,Du Yu7,Gao Zhipeng1ORCID,Ye Zhaoxiang1

Affiliation:

1. Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin’s Clinical Research Center for Cancer, Tianjin, China

2. Department of Laboratory, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin’s Clinical Research Center for Cancer, Tianjin, China

3. Department of Radiology, China Resources Wuhan Iron and Steel General Hospital, Wuhan, China

4. Department of Radiology, Shanxi Cancer Hospital, Taiyuan, China

5. Department of Radiology, Edong Medical Group Central Hospital, Huangshi, China

6. GE Healthcare Life Science, Beijing, China

7. Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China

Abstract

To evaluate the influence of low-concentration contrast agents and low-tube-voltage computed tomography on chest enhancement examinations, we conducted a multicenter prospective study. A total of 216 inpatients enrolled from 12 different hospitals were randomly divided into four groups: A: voltage, 120 kVp; iohexol, 350 mgI/mL; B: voltage, 100 kVp, iohexol, 350 mgI/mL; C: voltage, 120 kVp, iodixanol, 270 mgI/mL; and D: voltage, 100 kVp, iodixanol, 270 mgI/mL. Subjective image quality was assessed by two radiologists and compared by weighted kappa test. The objective image scores, scanning radiation doses, and pathological coincidence rates were analyzed. There were no significant differences in gender, age, height, weight, and body mass index between the four groups (p > 0.05). The consistency of the radiologists’ ratings were good, with kappa value ranging from 0.736 (95% confidence interval: 0.54–0.933) to 0.809 (95% confidence interval: 0.65–0.968), and there was no difference in subjective image score between the four groups. The computed tomography value of group D had no difference with group A. The volume computed tomography dose index, dose length product, and effective dose of group D (6.93 ± 3.03, 241.55 ± 104.75, and 3.38 ± 1.47, respectively) were all significantly lower than those of group A (10.30 ± 4.37, 359.70 ± 152.65, and 5.04 ± 2.14, respectively). There was no significant difference in the imaging diagnosis accuracy rate between the four groups (p > 0.05). The results indicated that low-concentration contrast agents (270 mgI/mL) and low-tube-voltage (100 kVp) computed tomography can not only decrease radiation dose but also guarantee the image quality and meet the needs of imaging diagnosis in chest enhancement examinations, which make it possible for its generalization and application.

Funder

Tianjin Science and Technology Major Project

Tianjin Medical University Cancer Institute and Hospital

Publisher

SAGE Publications

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3