Evaluation of Susceptibility Test Breakpoints Used to Predict mecA-Mediated Resistance in Staphylococcus Pseudintevmedius Isolated from Dogs

Author:

Bemis David A.12,Jones Rebekah D.12,Frank Linda A.32,Kania Stephen A.12

Affiliation:

1. From the Departments of Comparative Medicine

2. College of Veterinary Medicine, The University of Tennessee, Knoxville, TN.

3. Small Animal Clinical Sciences

Abstract

Clinical and Laboratory Standards Institute interpretive breakpoints for in vitro susceptibility tests that predict mecA-mediated oxacillin resistance in Staphylococcus pseudintermedius isolates from animals have been changed twice in the past decade. Moreover, there are no counterpart recommendations for human isolates of S. pseudintermedius. Individual medical and veterinary laboratories variably use interpretive breakpoints identical to those recommended for use with Staphylococcus aureus or identical to those recommended for use with coagulase-negative staphylococci. The purpose of the current study was to examine correlations between oxacillin disk diffusion, oxacillin gradient diffusion, oxacillin microbroth dilution, and cefoxitin disk diffusion tests used to predict mecA-mediated resistance in S. pseudintermedius and to retrospectively estimate, from disk diffusion zone diameter measurements, the prevalence and rate of increase of oxacillin resistance among canine S. pseudintermedius isolates submitted to a veterinary teaching hospital laboratory. Oxacillin disk diffusion zone diameters of ≤17 mm and oxacillin minimum inhibitory concentrations of ≥0.5 μg/ml were highly correlated with detection of mecA in canine S. pseudintermedius isolates by polymerase chain reaction. MecA-mediated resistance among S. pseudintermedius isolates from dogs increased from less than 5% in 2001 to near 30% in 2007. More than 90% of the methicillin-resistant S. pseudintermedius isolates in 2006 and 2007 were also resistant to representatives of ≥4 additional antimicrobial drug classes. Cefoxitin disk diffusion with the resistance breakpoint set at ≤24 mm significantly underestimated the presence of mecA in S. pseudintermedius.

Publisher

SAGE Publications

Subject

General Veterinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3