Toe Pressure Measurements Compared to Ankle Artery Pressure Measurements

Author:

Kröger Knut,Stewen Christian,Santosa Frans,Rudofsky Gottfried

Abstract

The Trans-Atlantic Inter-Society Consensus (TASC)-recommended absolute toe pressure is < 30-50 mm Hg for definition of chronic critical limb ischemia (CLI). Toe pressures can be measured by different techniques. The authors analyzed the clinical use of the Doppler technique and an automatic device with optical sensors and estimated their value in docu mentation of chronic critical limb ischemia compared to ankle artery pressures. Three different investigations were performed: (1) In 16 healthy subjects the digital artery pressures were measured by using 3 different optical sensors (transmission, reflection, and microcirculation sensor) and compared to the systolic brachial pressure. (2) In 50 patients with and without peripheral arterial occlusive disease the toe pressures at digits 1 and 2 of both feet were determined by Doppler technique (8 MHz) and by optical sensors (cuff width constant 1.5 cm) and were compared to the ankle artery pressure determined by Doppler technique. (3) In 175 patients the toe pressures were measured at 1 toe and the ankle artery pressures were deter mined. In this group they estimated the clinical use of the toe pressure in regard to the defi nition of CLI (toe pressure <50 mm Hg) compared to the ankle pressure <70 mm Hg. The digital artery pressures measured with the different optical sensors, and the systolic brachial pressures were not significantly different and the correlation coefficients were around 0.7. In 21 of 50 patients the toe pressure at D1 and D2 could not be measured by Doppler technique because with the applied cuff no Doppler signal could be detected at the tip of the toe, but in 24 of these 29 patients the optical measurement was possible. Mean toe pressures at D1 were 108 ±45 mm Hg and D2 102 ±45 mm Hg, which were statistically not different. The correlation coefficient for the highest ankle artery pressure and the highest toe pressure determined by the Doppler technique was 0.389; for the highest ankle artery pressure and the toe pressure measured by the optical sensors it was 0.369, and for the toe pressures measured by Doppler technique and the optical sensors it was 0.506. Defining systolic ankle artery pressure ≤ 50 to 70 mm Hg as the golden standard for CLI, the sensitivity of optical toe pressure measurement for the detection of CLI was 8%, the specificity was 96%, the positive predictive value 12%, and the negative predictive value was 94%. Independent of technique the absolute systolic toe pressures did not correlate with the absolute systolic ankle pressures. The optical measurement was more suitable for toe pressure measurement because it could be used in 90% of all patients. All in all, toe pressure measurements are more useful to exclude CLI than to prove it.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine

Cited by 42 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3