Assessment of the systolic rise time by photoplethysmography in peripheral arterial diseases: a comparative study with ultrasound Doppler

Author:

Amrani Samantha1,Eveilleau Kornelia2,Fassbender Verena1,Obeid Hasan2ORCID,Abi-Nasr Imad2,Giordana Pascal1,Hallab Magid2,Leftheriotis Georges1

Affiliation:

1. University Hospital of Nice, Vascular Medicine unit, Unité de Médecine et d’Explorations Vasculaires , CHU de Nice Pasteur 1, 30 voie Romaine Nice, France

2. Clinique Bizet, Cardiology unit , Paris, France

Abstract

Abstract Aims Peripheral arterial disease (PAD) is a major public health burden requiring more intensive population screening. Ankle brachial index (ABI) using arm and ankle cuffs is considered as the reference method for the detection of PAD. Although it requires a rigorous methodology by trained operators, it remains time-consuming and more technically difficult in patients with diabetes due to mediacalcosis. Techniques based on the study of hemodynamic, such as the systolic rise time (SRT), appear promising but need to be validated. We retrospectively compared the reliability and accuracy of SRT using a photoplethysmography (PPG) technique to the SRT measured by ultrasound doppler (UD) in PAD patients diagnosed with the ABI (137 patients, 200 lower limbs). Methods and results There was a significant correlation between SRT measured with UD (SRTud) compared with that with PPG (SRTppg, r = 0.25; P = 0.001). Best correlation was found in patients without diabetes (r = 0.40; P = 0.001). Bland and Altman analysis showed a good agreement between the SRTud and SRTppg. In contrast, there was no significant correlation between UD and PPG in diabetes patients. Furthermore, patients with diabetes exhibited a significant increase of SRTppg (P = 0.02) compared with patients without diabates but not with the SRTud (P = 0.18). The SRTppg was significantly linked to the arterial velocity waveforms, the type of arterial lesion but not vascular surgery revascularization technique. Conclusion This monocentric pilot study shows that SRT measured with the PPG signal reliably correlates with SRT recorded with UD. The PPG is an easy to use technique in the hand of non-expert with a potential interest for general screening of PAD, especially in diabetes patients, due to its ease to use.

Funder

University hospital of Nice

Publisher

Oxford University Press (OUP)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3