Chlorhexidine and silver sulfadiazine coating on central venous catheters is not sufficient for protection against catheter-related infection: Simulation-based laboratory research with clinical validation

Author:

Choi Yoon Ji1,Lim Jae Kwan2,Park Jeong Jun3,Huh Hyub3,Kim Dong-Joo4,Gong Chang-Hoon5,Yoon Seung Zhoo3

Affiliation:

1. Department of Anesthesia and Pain Medicine, Pusan National University Yangsan Hospital, Yangsan, Gyeongsangnam-do, Republic of Korea

2. Dental Life Science Research Institute, Seoul National University Dental Hospital, Seoul, Republic of Korea

3. Department of Anesthesiology and Pain Medicine, Anam Hospital, Korea University College of Medicine, Seoul, Republic of Korea

4. Brain and Cognitive Engineering, Korea University, Seoul, Republic of Korea

5. Medical Device Innovation Center, Korea University Anam Hospital, Seoul, Republic of Korea

Abstract

Objective The efficacy of chlorhexidine- and silver sulfadiazine-coated central venous catheters (CSS-CVC) against catheter-related infection remains controversial. We hypothesized that the loss of silver nanoparticles may reduce the antibacterial efficacy of CSS-CVCs and that this loss could be due to the frictional force between the surface of the CVC and the bloodstream. The objective of this study was to investigate whether the antimicrobial effect of CSS-CVCs decreases with increasing exposure time in a bloodstream model and quantitatively assay the antimicrobial effect of CSS-CVCs compared with polyurethane and antiseptic-impregnated CVCs. Methods Each CVC was subjected to 120 hours of saline flow and analyzed at intervals over 24 hours. The analyses included energy-dispersive X-ray spectroscopy, scanning electron microscopy, and optical density after a Staphylococcus aureus incubation test. Results The weight percentage of silver in the CSS-CVCs significantly decreased to 56.18% (44.10% ± 3.32%) with 48-hour catheterization and to 18.88% (14.82% ± 1.33%) with 120-hour catheterization compared with the initial weight percentage (78.50% ± 6.32%). In the S. aureus incubation test, the antibacterial function of CSS-CVCs was lost after 48 hours [3 (N/D) of OD]. Similar results were observed in a pilot clinical study using 18 CSS-CVCs. Conclusions We found that the efficacy of CSS-CVCs decreased over time and that the antibacterial function was lost after 48 hours of simulated wear-out. Therefore, antibiotic-impregnated CVCs may be a better option when longer (>48 hours) indwelling is needed.

Funder

Korea Evaluation Institute of Industrial Technology

Publisher

SAGE Publications

Subject

Biochemistry, medical,Cell Biology,Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3