Evaluation of an ex-vivo neonatal extracorporeal membrane oxygenation circuit on antiepileptic drug sequestration

Author:

Kalaria Shamir N12ORCID,Kishk Omayma A2,Gopalakrishnan Mathangi1,Bagdure Dayanand N3

Affiliation:

1. Center for Translational Medicine, School of Pharmacy, University of Maryland, Baltimore, MD, USA

2. Department of Pharmacy Services, University of Maryland Medical Center, Baltimore, MD, USA

3. Department of Pediatrics, School of Medicine, University of Maryland, Baltimore, MD, USA

Abstract

Antiepileptic dosing information used to manage neonatal patients receiving extracorporeal membrane oxygenation (ECMO) is limited. The objective of this study is to quantify the extent of sequestration of various antiepileptic drugs using an ex-vivo neonatal ECMO circuit. Two neonatal closed-loop ECMO circuits were prepared using a Rotaflow centrifugal pump, custom polyvinylchloride tubing and a Quadrox-i Neonatal membrane oxygenator. After 5 minutes of circuit priming and stabilization with normal saline/albumin or expired human whole blood, single boluses of levetiracetam (200 mg), lacosamide (20 mg), and phenytoin (200 mg) were injected into the circuit. To account for spontaneous drug degradation, two polyvinylchloride beakers were filled with normal saline/albumin or expired human whole blood and equivalent antiepileptic drug doses were prepared. Simultaneous pharmacokinetic samples were collected from the control solution and the pre-centrifugal pump, pre-oxygenator, and post-oxygenator sampling ports from each circuit. Similar drug recovery profiles were observed among the three sampling sites investigated. Percent drug sequestration after a 24-hour circuit flow period was relatively similar between the two different circuits and ranged between 5.5%–13.2% for levetiracetam, 18.4%–22.3% for lacosamide, and 24.5%–30.2% for phenytoin. A comparison at 12 and 24 hours demonstrated similar percent drug sequestration across all three drugs in each circuit. Percent drug sequestrations for levetiracetam and lacosamide were less than 20% and for phenytoin were as high as 30% based on the sampling following single bolus dose administration into a neonatal ECMO circuit. Careful consideration of patient clinical status should be taken in consideration when optimizing antiepileptic therapy in neonates receiving ECMO.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3