Outcome of right ventricular assist device implantation following left ventricular assist device implantation: Systematic review and meta-analysis

Author:

Reid Gregory1,Mork Constantin1,Gahl Brigita1,Appenzeller-Herzog Christian2ORCID,von Segesser Ludwig K3ORCID,Eckstein Friedrich1,Berdajs Denis A1ORCID

Affiliation:

1. Department of Cardiac Surgery, University Hospital Basel, Basel, Switzerland

2. University Medical Library, University Library of Basel, Basel, Switzerland

3. Department of Surgery and Anesthesiology Cardio-Vascular Research, University Hospital Lausanne, CHUV, Switzerland

Abstract

Objectives: The main aim was a systematic evaluation of the current evidence on outcomes for patients undergoing right ventricular assist device (RVAD) implantation following left ventricular assist device (LVAD) implantation. Methods: This systematic review was registered on PROSPERO (CRD42019130131). Reports evaluating in-hospital as well as follow-up outcome in LVAD and LVAD/RVAD implantation were identified through Ovid Medline, Web of Science and EMBASE. The primary endpoint was mortality at the hospital stay and at follow-up. Pooled incidence of defined endpoints was calculated by using random effects models. Results: A total of 35 retrospective studies that included 3260 patients were analyzed. 30 days mortality was in favour of isolated LVAD implantation 6.74% (1.98–11.5%) versus 31.9% (19.78–44.02%) p = 0.001 in LVAD with temporary need for RVAD. During the hospital stay the incidence of major bleeding was 18.7% (18.2–19.4%) versus 40.0% (36.3–48.8%) and stroke rate was 5.6% (5.4–5.8%) versus 20.9% (16.8–28.3%) and was in favour of isolated LVAD implantation. Mortality reported at short-term as well at long-term was 19.66% (CI 15.73–23.59%) and 33.90% (CI 8.84–59.96%) in LVAD respectively versus 45.35% (CI 35.31–55.4%) p ⩽ 0.001 and 48.23% (CI 16.01–80.45%) p = 0.686 in LVAD/RVAD group respectively. Conclusion: Implantation of a temporary RVAD is allied with a worse outcome during the primary hospitalization and at follow-up. Compared to isolated LVAD support, biventricular mechanical circulatory support leads to an elevated mortality and higher incidence of adverse events such as bleeding and stroke.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine