Using near-infrared reflectance spectroscopy (NIRS) to assess distal-limb perfusion on venoarterial (V-A) extracorporeal membrane oxygenation (ECMO) patients with femoral cannulation

Author:

Patton-Rivera Killian1,Beck James1,Fung Kenmond1,Chan Christine1,Beck Matthew1,Takayama Hiroo1,Takeda Koji1

Affiliation:

1. New York Presbyterian-Columbia University Medical Center, New York, NY, USA

Abstract

Background: Patients requiring V-A ECMO who receive femoral cannulation have an associated risk of distal, lower-limb hypoperfusion and ischemia of the cannulated leg. This pilot study evaluated the usefulness of non-invasive lower-limb oximetry, using near-infrared reflectance spectroscopy (NIRS) to detect limb ischemia. Methods: Between June 2016 and January 2017, 25 patients receiving femoral V-A ECMO were continuously monitored using the CASMED Fore-Sight Elite (CAS Medical Systems Inc., Branford, CT) tissue oximeter. A retrospective pilot study was conducted to review the correlation between NIRS tissue saturations (StO2) and clinical indications of limb ischemia. Patients were monitored for StO2s less than 50% for more than four minutes or StO2 differentials between the cannulated and non-cannulated legs greater than 15%. Results: Twenty-five patients (age 22-78) were monitored with NIRS. Six patients had clinical indications of lower-limb ischemia: cold limb, mottled skin and pulseless Doppler ultrasound. All six patients had StO2s below 50% that persisted for longer than four minutes. Of the 25 patients, one patient had a false-positive indication of hypoperfusion with StO2 below 50% for more than four minutes due to a venous saturation below 30%. Another patient had a false-positive pulseless Doppler ultrasound caused by high doses of pressor support. The StO2 was greater than 60%, which confirmed the clinical determination of adequate perfusion. Five patients had StO2s below 50% for less than four minutes and none of these patients had clinical indications of lower-limb hypoperfusion. All patients with cannula-related obstruction of flow to the distal portion of the leg had StO2 differentials greater than 15%. No patients without cannula-related obstruction to flow had StO2 differentials greater than 15%. Conclusion: Advancements in NIRS technology seem to have improved its accuracy for continuous, non-invasive monitoring of regional tissue and may provide clinicians with an additional metric to protect the distal portion of the cannulated leg.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3