Vacuum-assisted venous drainage in extrathoracic cardiopulmonary bypass management during minimally invasive cardiac surgery

Author:

Colangelo Nicola1,Torracca Lucia2,Lapenna Elisabetta2,Moriggia Stefano2,Crescenzi Giuseppe2,Alfieri Ottavio2

Affiliation:

1. Department of Cardiac Surgery and Cardiovascular Perfusion, San Raffaele University Hospital, Milan, Italy,

2. Department of Cardiac Surgery and Cardiovascular Perfusion, San Raffaele University Hospital, Milan, Italy

Abstract

The diffusion of minimally invasive cardiac surgery (MICS) during open-heart surgery has increased the use of assisted venous drainage support for cardiopulmonary bypass (CPB). Peripheral cannulation with small cannulae and vacuum-assisted venous drainage (VAVD) during MICS has been adopted in our institution since 1998. After the Heartport technique (HP) experience, the trans-thoracic clamp technique is now currently used. The aim of this study is to report our experience with extrathoracic CPB with VAVD application (on CPB) during open-heart MICS. From October 1999 to June 2006, 193 patients underwent MICS. Thirty-seven (19.2%) patients were treated with the HP - 13 (35%) with robotic technology and 156 (80.8%) with trans-thoracic aortic clamping (TTAC). Mean age was 39 years (range: 12-77), and 114 patients (59.1%) were female. A total of 128 patients (66.3%) underwent mitral valve surgery, 57 (29.6%) atrial septal defect closure, five (2.6%) cardiac mass removal, and three (1.5%) tricuspid valve repair. Four patients (2.0%) had a previous cardiac procedure. Peripheral CPB was established with a standard coated circuit. A 14 Fr arterial cannula was inserted into the right jugular vein and positioned at the atrial/superior vena cava junction. A 21 or 28 percutaneous femoral cannula, depending on body surface area, was inserted in the femoral vein and an arterial cannula in the right femoral artery. Gravitational drainage was combined with VAVD. To improve the safety and effectiveness of this technique, we monitored the pressure on each venous cannula and in the reservoir. The mean CPB time was 74.8∓30 min (TTAC) and 119∓48 min (HP); mean aortic clamping time was 51∓19 min (TTAC) and 73∓29 min (HP). We did not record any neurological complication. Two patients (1.0%), one from each group, were converted to sternotomy. Three patients (1.5%) underwent re-exploration for bleeding. In-hospital mortality was 0.5% (N = 1) (HP). Mechanical ventilation time and intensive care unit stay were comparable to those recorded with conventional sternotomy. In conclusion, we found that extrathoracic CPB and VAVD during trans-thoracic clamping is a safe, simple, and effective technique for MICS. However, there is a potential risk of haemolysis and air embolism, which can be prevented with vacuum monitoring, and with the addition of gravitational drainage to reduce vacuum pressure.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3