A survey of local diagnostic reference levels for the head, thorax, abdomen and pelvis computed tomography in Norway and Canada

Author:

Tonkopi Elena123,Wikan Eline Jahre4,Hovland Tor Olav4,Høgset Sivert4,Kofod Thomas Alexander4,Sefenu Selasi K4,Hughes-Ryan Emily5,d´Entremont-O´Connell Dakota5,Gunn Catherine25,Holter Tanja6,Johansen Safora47ORCID

Affiliation:

1. Department of Diagnostic Imaging, Nova Scotia Health Authority, Halifax, NS, Canada

2. Department of Radiation Oncology, Dalhousie University, Halifax, NS, Canada

3. Department of Diagnostic Radiology, Dalhousie University, Halifax, NS, Canada

4. Health faculty, Oslo Metropolitan University, Oslo, Norway

5. School of Health Sciences, Dalhousie University, Halifax, NS, Canada

6. Department of Physics and Computational Radiology, Oslo University Hospital, Oslo Norway

7. Department of Cancer Treatment, Oslo University Hospital, Oslo, Norway

Abstract

Background Computed tomography (CT) contributes to 60% of the collective dose in medical imaging. Literature has demonstrated that patient dose varies across regions and countries. Establishing diagnostic reference levels (DRLs) contributes to the optimization of clinical practices and radiation protection. Purpose To survey the dose indices (CTDIvol and dose-length product) for frequently performed CT examinations from the chosen hospitals in Norway and Canada and to determine local DRLs (LDRLs) based on the collected data. Material and Methods The survey included eight scanners from two Norwegian hospitals and four scanners from four Canadian hospitals. Dosimetry data were collected for the following routine CT examinations: head, contrast-enhanced thorax, and abdomen and pelvis. Overall 480 adult average-sized patients from Norway and 360 from Canada were included in the survey. The LDRLs were determined as the 75th percentile of distributions of median values of dose indicators from different CT scanners. The differences in dose between scanners were determined using single-factor ANOVA. Results The LDRLs determined in Norway were higher overall than in Canada. The obtained values were compared to the national DRLs. The dose from several scanners in Norway exceeded national Norwegian DRLs, while Canadian LDRLs were below the Canadian reference levels. The differences between the means of the dose distributions from each scanner were statistically significant ( p < 0.05) for all examinations with exception of identical scanners located in the same hospital and using the same protocols. Conclusion Observed dose variations even in the same hospital, or from the same scanner model confirmed the need for CT protocol optimization.

Publisher

SAGE Publications

Subject

General Earth and Planetary Sciences,General Environmental Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3