Evaluation of a Novel Cryoablation System: In vivo Testing in a Chronic Porcine Model

Author:

Weimar Timo1,Lee Anson M.1,Ray Shuddhadeb1,Schuessler Richard B.1,Damiano Ralph J.1

Affiliation:

1. Division of Cardiothoracic Surgery, Department of Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St Louis, MO USA.

Abstract

Objective Cryoablation is commonly used at present in the surgical treatment of atrial fibrillation (AF). However, there have been few studies examining the efficacy of the commonly used ablation devices. This report compares the efficacy of two cryoprobes in creating transmural endocardial lesions on the beating heart in a porcine model for chronic AF. Methods In six Hanford miniature swine, the right atrial appendage and the inferior vena cava were isolated using a bipolar radiofrequency clamp to create areas of known conduction block. A connecting ablation line was performed endocardially via a purse string with the novel malleable 10-cm Cryo1 probe for 2 minutes at −40°C. Additional ablation lines were created with the Cryo1 and the 3.5-cm 3011 Maze Linear probe on the right and the left atrial wall. Epicardial activation mapping was performed before and immediately after ablation as well as 14 days postoperatively. Histologic examination was performed 14 days postoperatively. Results Transmural lesions were confirmed in 83/84 cross-sections (99%) for the Cryo1 probe and in 40/41 cross-sections (98%) for the 3011 Maze Linear probe. There was no difference between the devices in lesion width (mean ± SD, Cryo1, 10.7 ± 3.5 mm; 3011, 10.0 ± 3.9mm; P = 0.31), lesion depth (Cryo1, 4.5 ± 1.7 mm; 3011, 4.6 ± 1.5 mm; P = 0.74), or atrial wall thickness (Cryo1, 4.5 ± 1.8 mm; 3011, 4.7 ± 1.7 mm; P = 0.74). There was a conduction delay across the right atrial ablation line (20 ± 2 milliseconds vs 51 ± 8 milliseconds, P < 0.001) that remained unchanged at 14 days (51 ± 8 milliseconds vs 52 ± 10 milliseconds, P = 0.88). Conclusions The Cryo1 probe created transmural lesions on the beating heart, resulting insustained conduction delay. Both probes had a similar performance in lesion geometry in this chronic animal model.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3