Infrared thermography: a rapid and accurate technique to detect feline aortic thromboembolism

Author:

Pouzot-Nevoret Céline12,Barthélemy Anthony12,Goy-Thollot Isabelle12,Boselli Emmanuel2,Cambournac Maxime12,Guillaumin Julien3,Bonnet-Garin Jeanne-Marie2,Allaouchiche Bernard24

Affiliation:

1. Intensive Care Unit (SIAMU), University of Lyon, VetAgro Sup, APCSe, Marcy l’Etoile, France

2. University of Lyon, VetAgro Sup, APCSe, Marcy l’Étoile, France

3. Emergency and Critical Care, Department of Veterinary Clinical Sciences, College of Veterinary Medicine, The Ohio State University, Columbus, OH, USA

4. Civilian Hospital of Lyon, Central Hospital of South Lyon, Medical Resuscitation Service, Pierre-Bénite, France

Abstract

Objectives The objective of this study was to evaluate the diagnostic accuracy of infrared thermography in cats with acute pelvic paralysis to differentiate feline aortic thromboembolism (FATE) from non-ischaemic conditions. Methods Thermographic images were prospectively obtained at admission from cats presented for acute bilateral pelvic paralysis. Based on the final diagnosis, cats were divided into a FATE and a control group (ischaemic and non-ischaemic related pelvic paralysis, respectively). The maximum (Tmax), minimum (Tmin) and average (Tav) temperatures were determined for each of the four limbs within a hand-drawn region of interest on the dorsal limb extremity. Temperature differences between the forelimb (non-affected) and hindlimb (affected) with the highest temperature (ΔT), with the lowest temperature (δT) and from the right and left side (RightΔT and LeftΔT, respectively) were calculated. Results The FATE and control groups included 10 and six cats, respectively. In the FATE group, right hindlimb mean Tmax (23.6°C ± 1.9), left hindlimb mean Tmax (23.6°C ± 2.2) and mean Tav (22.7°C ± 2.2) were significantly lower than in the control group (26.6°C ± 3.5 [ P = 0.042]; 26.6°C ± 2.4°C [ P = 0.024] and 25.7°C ± 2.0 [ P = 0.020], respectively). ΔT, δT, RightΔT and LeftΔT were significantly higher in the FATE group than in the control group. A cut-off value of 2.4°C for RightΔTmax and LeftΔTmax allowed discrimination between the FATE and control groups with a sensitivity of 80% and 90%, respectively, a specificity of 100% for both, a positive predictive value of 100% for both, and a negative predictive value of 75% and 86%, respectively. Conclusions and relevance A minimal difference of 2.4°C between ipsilateral affected and non-affected limbs has an excellent specificity and high sensitivity for FATE diagnosis. Infrared thermography seems to be a promising, useful, easy, non-invasive and rapid method for detecting aortic thromboembolism in cats, particularly in emergency situations.

Publisher

SAGE Publications

Subject

Small Animals

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3