Ultrasonographically derived caudal vena cava parameters acquired in a standing position and lateral recumbency in healthy, lightly sedated cats: a pilot study

Author:

Hultman Tove M1,Boysen Søren R2ORCID,Owen Rebecca1,Yozova Ivayla D1ORCID

Affiliation:

1. Veterinary Teaching Hospital, School of Veterinary Science, Massey University, Palmerston North, New Zealand

2. Department of Veterinary Clinical and Diagnostic Sciences, Faculty of Veterinary Medicine, University of Calgary, Calgary, AB, Canada

Abstract

Objectives The aim of this study was to determine the feasibility of ultrasonographically measuring the caudal vena cava (CVC) at the subxiphoid view of healthy, lightly sedated cats in a standing position and lateral recumbency. Methods This was a prospective, observational, experimental single-centre study. Twenty healthy research-purposed cats were enrolled. Two trained operators scanned each cat in two positions – standing and lateral recumbency – in a randomised order. CVC diameter was measured at the narrowest diameter during inspiration and at the widest diameter during expiration, at two anatomical locations along the CVC – where the CVC crosses the diaphragm (base) and 2 mm caudal to the diaphragm. The CVC collapsibility index (CVC-CI) was calculated for each site. Normalcy was assessed with a Shapiro–Wilk test. A one-way ANOVA with post-hoc Tukey’s test was used to compare inspiratory with expiratory values within and between groups. A paired t-test compared the CVC-CI between groups ( P ⩽0.05 indicated statistical significance). Spearman’s correlation and Bland–Altman analysis assessed inter-operator variability. Results All ultrasonographic data passed normalcy and were reported as mean ± SD. When compared with each other, inspiratory and expiratory values were statistically different for position, location and operator (all P <0.0001). There was no statistically significant difference between lateral recumbency or standing position for inspiratory, expiratory and CVC-CI values. Inter-operator variability was substantial, with operator 2 consistently obtaining smaller measurements than operator 1. The mean CVC-CI in lateral recumbency at the base was 24% for operator 1 and 37% for operator 2. For the same site in standing position, CVC-CI was 27% and 41% for operators 1 and 2, respectively. Conclusions and relevance This pilot study demonstrates that it is possible to ultrasonographically measure the CVC diameter in both lateral recumbency and a standing position in healthy, lightly sedated cats. However, measurements obtained are operator dependent with variability between individuals. Further studies are needed to determine if ultrasonographic CVC assessment will prove helpful in estimating intravascular volume status in cats.

Funder

massey university

Publisher

SAGE Publications

Subject

Small Animals

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3