Establishment of reference intervals for ultrasonographically derived caudal vena cava parameters from 110 healthy, lightly sedated cats

Author:

Hultman Tove M1,Rosanowski Sarah M2,Jalava Steffi M1,Boysen Søren R3ORCID,Yozova Ivayla D1ORCID

Affiliation:

1. Veterinary Teaching Hospital, School of Veterinary Science, Massey University, Palmerston North, New Zealand

2. Digital Agriculture, Grasslands Research Centre, AgResearch Limited, Palmerston North, New Zealand

3. Department of Veterinary Clinical and Diagnostic Sciences, Faculty of Veterinary Medicine, University of Calgary, Calgary, AB, Canada

Abstract

Objectives The present study aimed to establish reference intervals (RIs) for ultrasonographically derived caudal vena cava (CVC) parameters in healthy cats. Methods A prospective, observational, experimental single-centre study involving 110 cats was conducted. Two trained operators scanned all cats in a randomised order. Two sets of cine loops per cat were conducted by each operator from the subxiphoid view with cats in lateral recumbency. Two blinded raters measured the narrowest inspiratory (CVCinsp) and widest expiratory (CVCexp) diameter over two separate respiratory cycles for each operator (four measurements in total for each rater) at the point the CVC crosses the diaphragm. The CVC collapsibility index (CVCCI) was calculated. Reference intervals and limits were calculated for CVC parameters with outliers removed to include the central 95% of CVC values and the non-parametric 90% confidence intervals (90% CIs). The CVCCI interval included the central 95th (2.5th and 97.5th) centiles bounded by the 90% CI. Intra- and inter-rater and intra- and inter-operator reliabilities were calculated for each parameter using a two-way random-effects model. A Bland–Altman plot was used to visualise the CVCCI between the two raters. Results In total, 880 measurements were included for each diameter and 440 CVCCI values were calculated. The CVC diameters were normally distributed, whereas the CVCCI was not. The calculated RIs were 1.4–6.1 mm for CVCinsp and 2.2–6.7 mm for CVCexp. The median (range) CVCCI was 23% (11–36%) with 2.5th and 97.5th centiles of 2% and 67%, respectively. There was a moderate to good intra-rater and intra-operator reliability for CVC diameter. The intra-rater reliability for the CVCCI was moderate. The inter-rater and inter-operator reliabilities for the CVCCI were poor. Conclusions and relevance The CVC RIs determined from the subxiphoid site in cats appear to be wider than those reported in dogs, and rater and operator variability is present. Whether precise measurements of CVC parameters are suitable to guide clinical decisions remains to be determined.

Funder

Massey University Wenzel Research Fund

Publisher

SAGE Publications

Subject

Small Animals

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3