Affiliation:
1. Kimberly-Clark Corporation, Neenah, WI, USA
Abstract
The quality of a paper towel is often judged based on how quickly it can wipe up a spill. However, the test methods currently available cannot repeatably measure significant differences in absorbent rate between samples. Recent round-robin testing evaluations by TAPPI and CEN organizations have shown that past methods, such as ASTM D5802–95 and TAPPI T561-pm [1], are unreliable due to high variability. The reasons for the lack of repeatability are unclear. The relation between the wicking mechanism and the fundamental absorbent properties needs to be better understood. This paper uses x-ray imaging to show the overall flow characteristics of fluid absorption within a towel, and compares the results to model predictions to show which parameters are important to the process. From this understanding, a revised test method is proposed that provides adequate statistical discernment of absorbent rate properties of tissue on a simple lab-bench scale device.
Subject
General Materials Science
Cited by
12 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献