Dynamic simulation of the circulating fluidized bed loop performance under the various operating conditions

Author:

Kim Seongil1ORCID,Choi Sangmin1ORCID,Lappalainen Jari2,Song Tae-Ho1

Affiliation:

1. Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea

2. Department of Systems engineering and simulation, VTT Technical Research Centre of Finland Ltd., Espoo, Finland

Abstract

In a circulating fluidized bed boiler, the large thermal mass and flow characteristics of the solids strongly affect the transient response of the circulating fluidized bed loop temperature, which determines the heat transfer rate to steam flow. Therefore, it is essential to interpret the dynamic response of the solid behavior in the circulating fluidized bed loop for the stable and efficient operation of the circulating fluidized bed boiler. In this study, the dynamic simulation of the solid behavior along with the flue gas flow in a circulating fluidized bed loop was performed by applying the core-annulus approach for the solid-gas flow inside the furnace and selected models for other physical phenomena of the fluidized bed. The circulating fluidized bed loop of a commercial boiler was selected as the target system. Especially, the model simulates the characteristics of the solid behavior, such as the local solid mass distribution, and the solid flow inside the furnace and the circulating solid according to the various operating conditions. These aspects are difficult to measure and quantify in a real power plant. In this paper, the simulated furnace temperature behavior as the representative performance parameter of the circulating fluidized bed loop was discussed along with the qualitative operation experiences reported in the literature. The operating conditions include the feed rate of fuel and air, the particle size, the solid inventory and the solid circulation rate. Furnace temperature behavior was reproduced through the simulation for each operating case in the literature and was analyzed with the solid behavior along with the combustion rate and heat transfer rate of the circulating fluidized bed loop. The simulation enables quantitative evaluation of the effect of the solid behavior on the temperatures of the furnace and return part in the various operating conditions.

Publisher

SAGE Publications

Subject

Mechanical Engineering,Energy Engineering and Power Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3