Effect of the variability in implantation depth of intracorneal ring segments using the femtosecond laser technology in corneal ectasia

Author:

Peris-Martínez Cristina12,Dualde-Beltrán Cristina3,Fernández-López Ester1,Roig-Revert Maria José1,Hernández-Díaz Mikhail12,Piñero David P4

Affiliation:

1. Cornea and External Diseases Unit, FISABIO-Oftalmología Médica (FOM), Valencia, Spain

2. Clínica Oftalmológica Aviñó&Peris, Valencia, Spain

3. Hospital Universitario Doctor Peset, Valencia, Spain

4. Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain

Abstract

Purpose: To analyze the impact of the depth of implantation of intracorneal ring segments on morphological, biomechanical, and clinical outcomes in ectatic corneas. Methods: This prospective longitudinal study enrolled 40 eyes of 29 patients (age 20–51 years) with corneal ectasia that underwent intracorneal ring segments implantation (KeraRing, Mediphacos). Changes in visual acuity, refraction, corneal tomography, and corneal biomechanics (Ocular Response Analyzer, Reichert) were evaluated during a 6 month follow-up. Likewise, changes in ring segment implantation depth measured by optical coherence tomography (Visante OCT, Carl Zeiss Meditec) were also evaluated. Results: Mean relative depth of implantation was 71.6 ± 5.8%, 71.5 ± 6.5%, and 71.9 ± 6.3% at 1, 3, and 6 months after surgery, respectively (p = 0.827). The difference between the real relative depth of implantation and the theoretical attempted value of 70% was not statistically significant (p = 0.072). Differences in spherical equivalent during the follow-up changed significantly depending on the level of relative depth of implantation (p = 0.036), with an increase of 0.114 D per each 1% increase in relative depth of implantation. Likewise, a decrease of –0.194 D in the steepest keratometric reading was found per each decrease of 1% in relative depth of implantation (p = 0.026). Changes in corneal thickness (p = 0.092) and biomechanics (p = 0.080) were not related to relative depth of implantation. Conclusion: The effect on visual acuity and refraction of intracorneal ring segments when implanted in corneal ectasia is less clinically relevant when the implantation is done at a very deep plane. The variability of the depth of intracorneal ring segments implantation when using femtosecond laser technology is minimal and with no clinically significant effect on clinical outcomes.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3