Purpose: To evaluate visual, refractive, and topographic outcomes of intracorneal ring segment implantation in relation to the achieved segment depth, using the manual technique. Setting: Ophthalmology Department, Hospital de Braga, Braga, Portugal. Design: Retrospective cohort study. Methods: We obtained 104 eyes of 93 patients with keratoconus submitted to Ferrara intracorneal ring segment (ICRS) implantation, using a manual technique. Subjects were divided into 3 groups according to the achieved depth of implantation: 40% to 70% (Group 1), 70% to 80% (Group 2), and 80% to 100% (Group 3). Visual, refractive, and topographic variables were evaluated at baseline and 6 months. Topographic measurement was performed using Pentacam. Thibos-Horner and Alpins methods were used to analyze the vectorial change of refractive and topographic astigmatism, respectively. Results: We found a significant improvement of uncorrected distance visual acuity and corrected distance visual acuity in all groups at 6 months (P < .005); no differences were observed regarding safety and efficacy indexes in the 3 groups (P > .05). Manifest cylinder and spherical equivalent significantly reduced in all groups (P < .05). Topographic evaluation showed a significant improvement of all parameters in the 3 groups (P < .05). A shallower (Group 1) or deeper (Group 3) implantation was associated with topographic cylinder overcorrection, a higher magnitude of error, and a higher mean centroid postoperative corneal astigmatism. Conclusions: ICRS implantation with the manual technique showed to be equally effective in visual and refractive outcomes despite the depth of implantation; however, shallower or deeper implants were associated with topographic overcorrection and a higher mean centroid postoperative astigmatism, which explain the lower topographic predictability associated with manual surgery for ICRS implantation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Sensory Systems,Ophthalmology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3