Evaluation of biometric parameters in phacomorphic glaucoma and mature cataracts

Author:

Keleş Ali1ORCID,Şen Emine2,Elgin Ufuk2ORCID

Affiliation:

1. Department of Ophthalmology, Cizre State Hospital, Şırnak, Turkey

2. University of Health Sciences, Ulucanlar Eye Education and Research Hospital, Ankara, Turkey

Abstract

Purpose: The aims of this study were to compare the biometric parameters and axial lengths of eyes with phacomorphic glaucoma and mature cataract and to identify differences that might predispose to development of phacomorphic glaucoma. Methods: Three hundred forty-two patients were enrolled in this retrospective study. The eyes were divided into four groups—Group (G)1: phacomorphic glaucoma ( n = 29), G2: mature cataract ( n = 313), G3: contralateral phacomorphic glaucoma ( n = 29), and G4: contralateral mature cataract ( n = 313). Central corneal thickness and anterior chamber depth were assessed by optical low-coherence reflectometry (Lenstar LS 900®; Haag-Streit AG, Switzerland), while axial length was determined by A-scan ultrasound biometry. Results: The mean central corneal thickness of G1 was significantly higher than in other groups ( p < 0.001) and the mean anterior chamber depth of G1 was the lowest among the groups ( p < 0.001). Also, G2 had lower mean anterior chamber depth than G4 ( p < 0.001) and G3 had lower mean anterior chamber depth than G4 ( p = 0.007). Anterior chamber depth less than 3.27 mm had the higher odds ratio for distinguishing G3 versus G4 (odds ratio = 10.79, p < 0.001). Furthermore, patients aged ⩾68.9 years had the higher odds ratio for distinguishing G1 versus G2 (odds ratio = 2.82, p = 0.019). There was no significant difference in the presence of pseudoexfoliation material between G1 and G2 ( p = 0.057). There were no significant differences in axial length values among the four groups ( p = 0.097). Conclusion: Advanced age and shallow anterior chamber depth were found to be risk factors for developing phacomorphic glaucoma, but the presence of pseudoexfoliation material was not found to play a role as a risk factor in phacomorphic glaucoma development.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3