Human exposure to polyhexamethylene guanidine phosphate from humidifiers in residential settings: Cause of serious lung disease

Author:

Lee Ji Hyun1,Yu Il Je1

Affiliation:

1. Institute of Nanoproduct Safety Research, Hoseo University, Asan, Republic of Korea

Abstract

Exposure to the humidifier disinfectant, polyhexamethylene guanidine phosphate (PHMG), in mists generated from ultrasonic humidifiers was studied in a simulation chamber and apartment rooms. PHMG is suspected as a causative agent of lung disease in Korea residences. In the simulation-chamber study, the amount of disinfectant discharged from three different ultrasonic humidifiers was measured. Mists generated at 1, 2, and 4 times the recommended amount of disinfectant were sampled with an impinger, and the effect of relative humidity (RH) on airborne disinfectant concentration was studied by changing RH from 60%–70% to 90%–100%. In addition, particle size distribution (PSD) in mists was measured by scanning mobility particle sizer (SMPS), aerodynamic particle sizer (APS), and Mastersizer. In the apartment study, mists generated from ultrasonic humidifiers were sampled for 6 h in small and large rooms during fall ( n = 10) and winter ( n = 15). In the simulation study, the humidifiers discharged 205 ± 24.6 ml/h of mist at maximum capacity. Concentrations of airborne disinfectant increased with increasing concentration of disinfectant. RH affected airborne disinfectant concentration in the chamber, with increasing concentration with increasing RH. Below RH 70%, no airborne PHMG was detected. PHMG-containing mists generated from ultrasonic humidifier showed various sizes ranging from 149–157 nm to 690–740 nm to larger than 5.4 µm by SMPS, APS, and Mastersizer, respectively. Surface area mean diameter measured by Mastersizer ranged from 5.39 µm to 5.72 µm. In the apartment study conducted during the fall, the geometric mean (GM) and geometric standard deviation (GSD) and arithmetic mean (AM) and standard deviation (SD) of airborne PHMG concentration were 3.22 + 5.13 µg/m3 and 8.26 ± 12.18 µg/m3, respectively. In the winter, GM + GSD and AM ± SD of airborne PHMG concentration were 0.21 + 2.11 µg/m3 and 0.35 ± 0.62 µg/m3, respectively. RH and temperature in the apartment rooms for fall and winter were 22.5 ± 1.7°C, 74.5 ± 15.6% and 22.0 ± 2°C, 51.1 ± 12.9%, respectively. Different RHs in the fall and winter resulted in very different airborne concentrations of disinfectant in the apartment rooms. Exposure levels and PSD of mists generated from ultrasonic humidifiers in apartments are not sufficient to conclude that PHMG causes lung disease in Korean residences.

Publisher

SAGE Publications

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health,Toxicology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3