Affiliation:
1. Division of Urban Environment Research, Office of Sustainability Research, The Seoul Institute, Seoul, Republic of Korea
2. Institute of Health and Environment, Department of Environmental Health Sciences, Graduate School of Public Health, Seoul National University, Seoul, Republic of Korea
Abstract
The behavior of polyhexamethylene guanidine (PHMG), the causative agent of many humidifier-induced lung diseases, is not well known because of its various oligomer structures and analytical difficulties. The aim of this study was to identify different PHMG oligomer types both in solution and aerosols and to estimate the airborne concentration of oligomers during humidifier use. Three products containing PHMG as the main component were diluted to the manufacturer’s recommended concentration (6.5 ppm) or the worst-case concentration (65 ppm or 125 ppm). Samples were qualitatively and quantitatively analyzed with liquid chromatography-quadrupole time-of-flight (LC-qToF) mass spectrometry in the diluted solution and in the air at 0.5 m and 1 m. The LC-qToF data were processed using UNIFI software to characterize the PHMG structure. For all products in both the humidifier solution and air, the linear type was predominant over the branched/cyclic structure, but each product had different characteristics. The linear structure in the Oxy product, the main product of lung diseases, accounted for 90.6%, while that of the Scunder and BOC Sciences’ products accounted for 78.6% and 75.8%, respectively. The concentration of the oligomer in air for the Oxy product was estimated to be 35.89 and 390.96 μg/m3 at 6.5 and 65 ppm, respectively. Most of the oligomers in the solution were found in air at a short distance (0.5 m), with a negligible concentration beyond 1 m. Oligomers with 1–7 monomer units were identified in the humidifier solution, whereas mainly monomers, dimers, and trimers were identified in the air. The results of this study will facilitate further investigations of the mechanisms of lung disease by identifying the behaviors and forms of PHMG in the air, along with previously revealed toxicity results.
Reference32 articles.
1. Hypersensitivity pneumonitis due to an ultrasonic humidifier
2. Types of household humidifier disinfectant and associated risk of lung injury (HDLI) in South Korea
3. Association of high-level humidifier disinfectant exposure with lung injury in preschool children
4. Hypersensitivity pneumonitis associated with the use of ultrasonic humidifiers;S. T. Shiue;New York State Journal of Medicine,1990
5. Analysis of biocidal oligoguanidines and oligobiguanides by high-performance liquid chromatography and mass spectrometry;T. Buchberger;Mahidol University Journal of Pharmacy Science,2014