A Multi-Centre, Single-Arm Clinical Study to Confirm Safety and Performance of PuraStat®, for the Management of Bleeding in Elective Carotid Artery Surgery

Author:

Stenson Katherine M.1ORCID,Loftus Ian M.2,Chetter Ian3,Fourneau Inge4,Cavanagh Stephen5,Bicknell Colin6,Loftus Paros2

Affiliation:

1. St George's Vascular Institute, St George's Hospital, London, UK

2. St George's University of London, Cranmer Terrace, London, UK

3. Academic Vascular Surgical Unit, Hull Royal Infirmary, Hull, UK

4. Department of Vascular Surgery, University Hospitals Leuven, Leuven, Belgium

5. Vascular Surgery Unit, York Teaching Hospital NHS Foundation Trust, York, North Yorkshire, UK

6. Department of Vascular Surgery, St Mary’s Hospital, Imperial College London Healthcare NHS Trust, London, UK

Abstract

Anastomotic bleeding in vascular surgery can be difficult to control. Patients, in particular those undergoing carotid surgery, have often been started on treatment with dual antiplatelet agents and receive systemic heparinization intraoperatively. The use of local hemostatic agents as an adjunct to conventional methods is widely reported. 3-D Matrix’s absorbable hemostatic material RADA16 (PuraStat®), is a fully synthetic resorbable hemostatic agent. The aim of this study is to confirm the safety and performance of this agent when used to control intraoperative anastomotic bleeding during carotid endarterectomy (CEA). A prospective, single-arm, multicenter study involving 65 patients, undergoing CEA, in whom the hemostatic agent was applied to the suture line after removal of arterial clamps. Patients were followed up at 24 h, discharge, and one month after surgery. Time to hemostasis was measured as the primary endpoint. Secondary endpoints included hemostasis efficacy and safety outcomes, blood loss, intraoperative and postoperative administration of blood products, and incidence of reoperation for bleeding. A total of 65 cases (51 male and 14 female) undergoing CEA, utilizing patch reconstruction (90. 8%), eversion technique (6.1%), and direct closure (3.1%) were analyzed. All patients received dual antiplatelet therapy preoperatively and were administered systemic intravenous heparin intraoperatively, as per local protocol. The mean time to hemostasis was 83 s ± 105 s (95% CI: 55-110 s). Primary hemostatic efficacy was 90.8%. The mean volume of product used was 1.7 mL ± 1.1 mL. Hemostasis was achieved with a single application of the product in 49 patients (75.3%). Two patients required a transfusion of blood products intraoperatively. There were no blood product transfusions during the postoperative period. The intraoperative mean blood loss was 127 mL ± 111.4 mL and postoperatively, the total mean drainage volume was 49.0 mL ± 51.2 mL. The mean duration of surgery was 119 ± 35 min, and the mean clamp time was 35 min 12 s ± 19 min 59 s. In 90.8% of patients, there was no presence of hematoma at 24 h postoperatively. Three returned to theatre due to bleeding (2 in the first 24 h), however, none of these cases were considered product related. Overall, there were no device-related serious adverse events (SAE) or unanticipated device-related SAEs reported. Use of the hemostatic agent PuraStat® is associated with a high rate of hemostatic efficacy (90.8%) and a short time to hemostasis. The safety of the product for use on vascular anastomoses has been demonstrated.

Publisher

SAGE Publications

Subject

Hematology,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3