Affiliation:
1. Department of Architecture and Planning, Visvesvaraya National Institute of Technology, Nagpur, India
Abstract
Daylighting integrated with artificial lighting control is recognized as an important and useful strategy in energy-efficient building designs. The prediction of the internal daylight levels is a key stage in daylighting designs. For this research, the ‘type design’ residential quarters building as a case has been selected from Nagpur region in central India having a hot and dry climate. These ‘type design’ have the major issues related to the performance of daylight and thermal comfort due to lack of some rules related to sizes of fenestrations in the development control regulation. The aim of this research is to evaluate the most critical liveable area of a dwelling unit of ‘type design’ for daylight and thermal comfort. This research includes evaluation of the selected parameters by comparative analysis of useful daylight illuminance (UDI), daylight autonomy (DA), thermal comfort hours and carpet area to window ratio (CAWR) with the help of dynamic simulation by using ‘Daysim’, ‘radiance analysis tool’ and ‘temperature distribution tool’ of Ecotect 2011 software. The findings of this research arrive to derive the CAWR with respect to orientation (four cardinal directions) of the building without compromising the thermal comfort with respect to the temperature of a dwelling unit of ‘type design’.
Subject
Public Health, Environmental and Occupational Health
Cited by
4 articles.