Long-term results and comparison of flow re-direction endoluminal device and pipeline embolization device in endovascular treatment of intracranial carotid aneurysms

Author:

Gündoğmuş Cemal A1ORCID,Sabet Soheil1,Baltacıoğlu Nurten A2,Türeli Derya1ORCID,Bayri Yaşar3,Baltacıoğlu Feyyaz12

Affiliation:

1. Department of Radiology, Marmara University, School of Medicine, Turkey

2. Department of Radiology, VKV Amerikan Hastanesi, Turkey

3. Department of Neurosurgery, Marmara University, School of Medicine, Turkey

Abstract

Objective This study aims to compare the efficacy, safety, and long-term outcomes of two flow diverters, i.e., pipeline embolization device and flow re-direction endoluminal device, in the treatment of distal carotid aneurysms. Methods A total of 138 patients with 175 aneurysms were included from February 2012 to September 2019. Ninety-nine aneurysms were treated with flow re-direction endoluminal device and 76 with pipeline embolization device. Angiographic follow-ups were at the 6th, 12th, 24th, 36th, and 60th months; the O’Kelly-Marotta grading scale was used to assess aneurysms occlusion. Outcomes of two devices were compared; possible associations regarding patient characteristics, aneurysm properties, treatment details, and adverse events were evaluated. Results The mean follow-up period was 33 months, with 10 patients lost to follow-up. Occlusion rates at the 6th and 12th months and during the last follow-up were similar for flow re-direction endoluminal device (81%, 84%, and 90%) and pipeline embolization device (82%, 85%, and 93%). Occlusion rates were also similar after stand-alone use without coiling. There was no significant difference regarding adverse event rates with a 10.9% overall complication rate, 3.6% mortality, and 0.7% permanent morbidity. All the mortality and morbidity were related to hemorrhagic complications. Device deployment failure was observed with five flow re-direction endoluminal devices and two pipeline embolization devices, whereas two severe in-stent stenoses occurred with each device. Conclusions Both flow re-direction endoluminal device and pipeline embolization device are feasible and effective in flow diversion of distal internal carotid artery aneurysms, with similar adverse events rates and aneurysm occlusion success. Aneurysm occlusion rates increase with time, while the presence of an integrated branch significantly decreases treatment success.

Publisher

SAGE Publications

Subject

Immunology

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3