Estimating effective dose from 3D imaging with interventional fluoroscopy systems using limited exposure data

Author:

Svalkvist Angelica12,Hansson Jonny12,Båth Magnus12

Affiliation:

1. Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, SE-413 45 Gothenburg, Sweden

2. Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden

Abstract

Background Estimations of the effective dose from three-dimensional (3D) rotational imaging with interventional fluoroscopy systems are hampered by the fact that not all systems provide individual exposure values for each projection image included in the examination. Purpose To investigate the error in resulting effective dose introduced by not using individual exposure values for each projection image in the dose calculations for 3D rotational imaging with interventional fluoroscopy systems. Material and Methods An interventional fluoroscopy system was used to acquire images of two anthropomorphic phantoms. Calculations of the effective dose were performed using two different methods: 1, using individual exposure values for each projection image; and 2, using the mean tube voltage and the total dose-area product (DAP), evenly distributed over a selection of projection images. The second method was also tested in hypothetical examinations to investigate the effects of worst-case scenarios regarding the effect of exposure asymmetry on the error. Results The error in resulting effective dose obtained when simplifying the dose calculations by using Method 2 instead of Method 1 was within ±14%. The error increased slightly for the worst-case scenarios but was still smaller than ±20%, regardless of anatomical region, tube voltage variation, and patient size. Conclusion Given the uncertainties associated with the effective dose concept as well as of reported DAP values, the present study indicates that dose calculations based on average exposure values distributed over a smaller selection of projection angles can provide reasonably accurate estimations of the radiation doses from 3D imaging using interventional fluoroscopy systems.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3