Intraoperative Effect of 2D vs 3D Fluoroscopy on Quality of Reduction and Patient-Related Outcome in Calcaneal Fracture Surgery

Author:

Halm Jens A.1,Beerekamp M. Suzan H.1ORCID,de Muinck-Keijzer Robert Jan1,Beenen Ludo F. M.2ORCID,Maas Mario2,Goslings J. Carel3,Schepers Tim1

Affiliation:

1. Trauma Unit, Amsterdam University Medical Centers, Location AMC, Amsterdam, The Netherlands

2. Department of Radiology, Amsterdam University Medical Centers, Location AMC, Amsterdam, The Netherlands

3. Department of Surgery, Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands

Abstract

Background: Three-dimensional (3D) fluoroscopy is thought to be advantageous in the open reduction and internal fixation (ORIF) of calcaneal fractures. The goal of this multicenter randomized controlled trial was to investigate the clinical effect of additional intraoperative 3D fluoroscopy on postoperative quality of reduction and fixation and patient-reported outcome as compared to conventional 2-dimensional (2D) fluoroscopy in patients with intra-articular fractures of the calcaneus. Methods: Patients were randomized to 3D or conventional 2D fluoroscopy during operative treatment of calcaneal fractures. Primary outcome was the difference in quality of fracture reduction and implant position on postoperative computed tomography (CT). Secondary endpoints included intraoperative corrections (prior to wound closure), complications, and revision surgery (after wound closure). Function and patient-reported outcome were evaluated after surgery and included range of motion, Foot and Ankle Outcome Score (FAOS), American Orthopaedic Foot & Ankle Society (AOFAS) score, Short-Form 36 (SF-36) questionnaires, and Kellgren-Lawrence posttraumatic osteoarthritis classification. A total of 102 calcaneal fractures were included in the study in 100 patients. Fifty fractures were randomized to the 3D group and 52 to the 2D group. Results: There was a statistically significant difference in duration of surgery between the groups (2D 125 min vs 3D 147 min; P < .001). After 3D fluoroscopy, a total of 57 intraoperative corrections were performed in 28 patients (56%). The postoperative CT scan revealed an indication for additional revision of reduction or implant position in 69% of the 3D group vs 60% in the 2D fluoroscopy group. At 2 years, there was no difference in number of revision surgery, complications, FAOS, AOFAS score, SF-36 score, or posttraumatic osteoarthritis. Conclusion: The use of intraoperative 3D fluoroscopy in the treatment of intra-articular calcaneal fractures prolongs the operative procedures without improving the quality of reduction and fixation. There was no benefit of intraoperative 3D fluoroscopy with regard to postoperative complications, quality of life, functional outcome, or posttraumatic osteoarthritis. Level of Evidence: Level I, prospective randomized controlled study.

Funder

Philips Healthcare, Best, the Netherlands

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3