Comparison of automated breast ultrasonography to handheld ultrasonography in detecting and diagnosing breast lesions

Author:

Jeh Su Kyung1,Kim Sung Hun2,Choi Jae Jeong1,Jung Sang Sul3,Choe Byung Joo3,Park Sarah4,Park Mi Sun5

Affiliation:

1. Department of Radiology, Hallym University Medical Center, The Hallym University of Korea, Chuncheon, Republic of Korea

2. Department of Radiology, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea

3. Department of General Surgery, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea

4. Department of Internal Medicine, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea

5. Department of Biostatistics, Clinical Research Coordinating Center, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea

Abstract

Background Automated breast ultrasonography (ABUS) is increasingly used as a screening tool. Several studies have demonstrated a similar diagnostic performance for ABUS compared with handheld ultrasonography (HHUS), but the overall results have been controversial. Purpose To compare the clinical utility of ABUS and HHUS for detection and diagnosis of breast lesions. Material and Methods ABUS and HHUS images of suspicious breast lesions were obtained for 173 consecutive women scheduled to undergo ultrasonography (US)-guided or stereotactic biopsy. There were a total of 206 lesions, 46 of which were malignant and 160 benign. Three breast radiologists took part in this study: two reviewed the ABUS images, and the third reviewed all of the images, ABUS and HHUS, as well as the patients’ medical records. The biopsied-lesion-detection rates were obtained. Using the Breast Imaging Reporting and Data System (BI-RADS), the images of the biopsied lesions were evaluated. Factors affecting ABUS detectability were analyzed. Results The overall detection rates were 83.0% for ABUS and 94.2% for HHUS. Ten lesions were not detected on either HHUS or ABUS and these were microcalcifications (one malignancy and nine benign lesions). Of the 194 HHUS-detected lesions, 169 were detected by ABUS and 25 benign were not. ABUS less frequently detected lesions of smaller size as well as those of benign appearance and lower final-assessment category ( P = 0.011 and P < 0.0001, respectively). Conclusion ABUS detected all of the malignant lesions that were detected on HHUS. ABUS missed several smaller benign lesions.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 40 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献