Diagnostic accuracy of supplemental three-dimensional breast ultrasound in the work-up of BI-RADS 0 screening recalls

Author:

den Dekker Bianca M.ORCID,Broeders Mireille J. M.,Meeuwis Carla,Setz-Pels Wikke,Venmans Alexander,van Gils Carla H.,Pijnappel Ruud M.

Abstract

Abstract Objective To evaluate the diagnostic accuracy of supplemental 3D automated breast ultrasound (ABUS) in the diagnostic work-up of BI-RADS 0 recalls. We hypothesized that 3D ABUS may reduce the benign biopsy rate. Materials and methods In this prospective multicenter diagnostic study, screening participants recalled after a BI-RADS 0 result underwent bilateral 3D ABUS supplemental to usual care: digital breast tomosynthesis (DBT) and targeted hand-held ultrasound (HHUS). Sensitivity, specificity, positive predictive value, and negative predictive value of 3D ABUS, and DBT plus HHUS, were calculated. New 3D ABUS findings and changes of management (biopsy or additional imaging) were recorded. Results A total of 501 women (median age 55 years, IQR [51–64]) with 525 BI-RADS 0 lesions were included between April 2018 and March 2020. Cancer was diagnosed in 45 patients. 3D ABUS sensitivity was 72.1% (95% CI [57.2–83.4%]), specificity 84.4% (95% CI [80.8–87.4%]), PPV 29.2% (95% CI [21.4–38.5%]), and NPV 97.1% 95.0–98.4%). Sensitivity of DBT plus HHUS was 100% (95% CI [90.2–100%]), specificity 71.4% (95% CI [67.2–75.2%]), PPV 23.8% (95% CI [18.1–30.5%]) and NPV 100% (95% CI [98.7–100%]). Twelve out of 43 (27.9%) malignancies in BI-RADS 0 lesions were missed on 3D ABUS, despite being detected on DBT and/or HHUS. Supplemental 3D ABUS resulted in the detection of 57 new lesions and six extra biopsy procedures, all were benign. Conclusion 3D ABUS in the diagnostic work-up of BI-RADS 0 recalls may miss over a quarter of cancers detected with HHUS and/or DBT and should not be used to omit biopsy. Supplemental 3D ABUS increases the benign biopsy rate. Trial registration Dutch Trial Register, available via https://www.onderzoekmetmensen.nl/en/trial/29659 Critical relevance statement Supplemental 3D automated breast ultrasound in the work-up of BI-RADS 0 recalls may miss over a quarter of cancers detected with other methods and should not be used to omit biopsy; ABUS findings did increase benign biopsy rate. Key Points Automated breast ultrasound (ABUS) may miss over 25% of cancers detectable by alternative methods. Don’t rely solely on 3D ABUS to assess indication for biopsy. New findings with supplemental 3D ABUS increase the benign biopsy rate. Graphical Abstract

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3