Breast tomosynthesis for the clarification of mammographic BI-RADS 3 lesions can decrease follow-up examinations and enables immediate cancer diagnosis

Author:

Bahrs Sonja D1,Otto Vanessa1,Hattermann Valerie1,Klumpp Bernhard1,Hahn Markus2,Nikolaou Konstantin1,Siegmann-Luz Katja1

Affiliation:

1. Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Tuebingen, Germany

2. Department of Gynecology and Obstetrics, University Hospital Tuebingen, Tuebingen, Germany

Abstract

Background The limited sensitivity of mammography in case of a high breast density often produces unclear or false-positive findings, so-called BI-RADS 3 lesions, which have to be followed up to prove benignity. Digital breast tomosynthesis (DBT) was developed to reduce such summation effects. Purpose To evaluate the influence of an additional DBT on the management of mammographic BI-RADS 3 findings and whether DBT can decrease the time to definitive diagnosis or not. Material and Methods We analyzed 87 patients with a mammographic non-calcified BI-RADS 3 lesion who underwent an additional DBT of the affected breast. A follow-up two-dimensional (2D) examination or a histological result of the lesion had to be available. The images were analyzed especially for the BI-RADS category and incremental diagnostic accuracy. Moreover, the inter-reader reliability and the radiation dose were evaluated. Results The BI-RADS category has been changed by the addition of DBT: 57.1% were assessed as BI-RADS 1 or 2, 4.6% as BI-RADS 4, and only 38.3% remained as BI-RADS 3. The intraclass correlation coefficient for the three readers showed a good agreement for inter-reader reliability. No false-negative examination was found in the follow-ups. Nine lesions were biopsied (seven benign, two malignant). Both malignant lesions were suspicious in the DBT (BI-RADS 4). A significant higher glandular dose was necessary for the DBT. Conclusion DBT has the potential to reduce the recall-rate of BI-RADS 3 lesions and to find and diagnose malignant lesions earlier than 2D mammography alone.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3