Comparison of central and local serial CT assessments of metastatic renal cell carcinoma patients in a clinical phase IIB study

Author:

Felsch Moritz1,Zaim Souhil2,Dicken Volker3,Lehmacher Walter1,Scheuring Urban J4

Affiliation:

1. Institute of Medical Statistics, Informatics and Epidemiology, University of Cologne, Universitätsklinikum Köln, Köln, Germany

2. Synarc, Inc., Newark, California, USA

3. Fraunhofer MEVIS, Institute for Medical Image Computing, Bremen, Germany

4. Bayer HealthCare, Bayer Vital GmbH, Leverkusen, Germany

Abstract

Background Clinical oncological studies attempt to improve precision of data by central radiological assessments. However, it is unclear, to which extent local and central assessments diverge. Purpose To quantify inter-reader variability and the deviation of local from central radiological assessments of computed tomography (CT) scans. Material and Methods This was a sub-study of a randomized clinical phase IIb trial in metastatic renal cell carcinoma (RCC), comparing first-line sorafenib with interferon-alpha-2a (IFN-α-2a). It analyzed agreements of local with central RECIST CT assessments by Cohen’s kappa (κ), symmetry tests, deviations in waterfall plots, Bland–Altman plots, and parametric survival analyses. Results The concordance between local and central radiologic review was quantified by κ = 0.53. While local assessment yielded progressive disease (PD) in 18.6%, central assessment classified 22.5% of patient time points as PD exhibiting only a partial overlap with the 18.6% The tumor shrinkage rates in waterfall plots were 68.1% in local and 55.8% in central review (57.8% and 59% by Reader 1 and Reader 2). Bland–Altman plots identified a systematic shift of tumor change rates by −7.5% in local compared to central assessments, that may reflect a systematic tendency of more favorable results in local assessments. The discordance between local and central review was reflected by a time to progression (TTP) hazard ratio (HR) of 1.73 ( P = 0.0003). Conclusion These data suggest that central radiologic review may reduce technical measurement variability in clinical trials, which should be scrutinized in future studies compared to a volumetric reference.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3