Dosimetric Effects of Differences in Multi-Leaf Collimator Speed on SBRT-VMAT for Central Lung Cancer Patients

Author:

Saito Masahide1ORCID,Komiyama Takafumi1ORCID,Marino Kan1,Aoki Shinichi1,Oguri Mitsuhiko1,Yamada Takashi1,Sano Naoki1,Suzuki Hidekazu1,Ueda Koji1,Onishi Hiroshi1ORCID

Affiliation:

1. Department of Radiology, University of Yamanashi, Yamanashi, Japan

Abstract

Purpose: We aimed to investigate the effects of different multi-leaf collimator (MLC) speed constraints in volumetric modulated radiotherapy (VMAT) on the robustness of treatment plans for central lung cancer patients. Method and Materials: Twenty patients with central lung tumor who underwent stereotactic body radiotherapy (SBRT) with the VMAT technique at our hospital were included in this retrospective study. The reference plans were created with 3 different MLC speed constraints (Plan A: 0.1 cm/deg., Plan B: 0.3 cm/deg., and Plan C: 0.5 cm/deg.) with a 50-Gy/8Fr, planning target volume (PTV) D95% prescription. In each of these plans, setup errors from 1 to 5 mm were intentionally added in the direction of the central organ at 1-mm intervals (300 plans [20 cases × 3 MLC speeds × 5 error plans] were created in total). Each plan was then calculated by the same beam conditions as each reference plan. The actual average MLC speed and dose difference between the reference plan and the error-added plan were then calculated and compared among the 3 MLC speeds. Results: In the reference plans, the actual average MLC speeds were 0.25 ± 0.04, 0.34 ± 0.07, and 0.39 ± 0.12 cm/deg. for Plan A, Plan B, and Plan C, respectively ( P < .05). For PTV and OARs, many dose indices tended to improve as the MLC speed increased, while no significant differences were observed among the 3 MLC speed constraints. However, in assessments of robustness, no significant differences in dose difference were observed among the 3 MLC speed constraints for most of the indices. Conclusions: When necessary, increasing the MLC speed constraint with a priority on improving the quality of the dose distribution is an acceptable approach for central lung cancer patients.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3